Specification
PRINTED IN U.S.A. 12/17 WP FORM NO. RR102CE-3TB
2
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
Rheem Water Heating • 1115 Northmeadow Parkway, Suite 100
Roswell, Georgia 30076 • www.rheem.com
I N TEGR ATED AIR & WATER
INTEGRATED HOME COMFORT
Water
INTEGRATED HOME COMFORT
Commercial Electric
Light-Duty Water Heaters
Recommended Specifications (for trade reference only)
Water heater(s) shall be model _____________, manufactured by
Rheem, having electrical input of __________ kW and a recovery rate of
_____________ GPH at a 100°F temperature rise. Water heater(s) shall
have a storage capacity of __________ gallons. Water heater(s) shall
have the UL seal of certification and be factory equipped with an CSA/
ASME rated temperature and pressure relief valve. Tank(s) interior shall
be coated with a high temperature porcelain enamel and furnished with
a magnesium anode rod rigidly supported. Water heater(s) shall meet or
exceed the energy factor requirements of ASHRAE. Tanks shall have a
working pressure rating of 150 psi, and shall be completely assembled.
Water heater(s) shall be equipped with copper, resistored, “screw-in”
type elements. Tank shall be insulated with 2-1/2" of rigid polyurethane
foam insulation. Water heater(s) shall be equipped with surface mounted
thermostats each with an integral, manual reset, high limit control.
Water heater(s) shall be covered by a three year limited warranty against
tank leaks.
RECOVERY CAPACITIES (Recovery in U.S. Gallons/Hr. (GPH) and Liters/Hr. (LPH) at various temperature rises)
ELEMENT
WATTAGE
UPPER/LOWER
NON-SIMULTANEOUS WIRING SIMULTANEOUS WIRING
40°F / (22°C) 60°F / (33°C) 80°F / (45°C) 100°F / (56°C) 120°F / (67°C) 40°F / (22°C) 60°F / (33°C) 80°F / (45°C) 100°F / (56°C) 120°F / (67°C)
GPH LPH GPH LPH GPH LPH GPH LPH GPH LPH GPH LPH GPH LPH GPH LPH GPH LPH GPH LPH
3000/3000 30 115 20 77 15 58 12 46 10 38 61 230 41 153 30 115 24 92 20 77
4000/4000 41 153 27 102 20 77 16 61 14 51 81 307 54 205 41 153 32 123 27 102
4500/4500 46 173 30 115 23 86 18 69 15 58 91 345 61 230 46 173 36 138 30 115
5000/5000 51 192 34 128 25 96 20 77 17 64 101 384 68 256 51 192 41 153 34 128
6000/6000 61 230 41 153 30 115 24 92 20 77 122 460 81 307 61 230 49 184 41 153
6050/6050 61 230 41 153 30 115 24 92 20 77 122 460 81 307 61 230 49 184 41 153
ANODE ROD
COLD
WATER
CONNECITON
WATER CONNECTIONS 3/4" NPT
3/4" T&P
HOT
WATER
CONNECTION
8"
B DIA.
A
DIMENSIONAL INFORMATION (All dimensions shown in English and Metric)
FIRST
HOUR
DEL.
G.P.H.
UNIFORM
ENERGY
FACTOR
(UEF)
MODEL
NUMBER
MIN.
WATTS
MAX.
WATTS
TANK CAPACITY
(LISTED)
TANK CAPACITY
(MEASURED)
A B
APPROX.
SHIPPING WT.
GAL. LTR GAL. LTR INCHES MM INCHES MM lbs. kgs.
ELD30-TB 3,000 12,000 30 114 27 102 47-1/2 1207 19 483 125 57 46 0.92
ELD40-TB 3,000 12,000 40 151 36 136 48-1/4 1226 20-1/4 514 140 64 55 0.93
ELD52-TB 3,000 12,000 50 189 45 170 58-5/8 1489 20-1/4 514 155 70 63 0.93
ELD66-TB 12,100 12,100 65 246 58.5 221 59-3/8 1508 22-1/4 565 185 84 N/A N/A
ELD80-TB 12,100 12,100 80 303 72 273 59-5/8 1514 23-3/4 603 220 100 N/A N/A
ELD120-TB 12,100 12,100 119.9 454 108 409 62-7/8 1597 28-1/4 718 335 152 N/A N/A
ELDS30-TB 3,000 12,000 28 106 25 95 30 762 23 584 130 59 43 0.92
ELDS40-TB 3,000 12,000 36 136 33 125 31-1/2 800 24-1/4 616 150 68 46 0.92
ELDS52-TB 3,000 12,000 47 178 43 163 32 813 26-1/4 667 180 82 57 0.93
PRODUCT AVAILABILITY
SIZE
208V 240V 277V 480V
3/3 4/4 4.5/4.5 5/5 6/6 3/3 4/4 4.5/4.5 5/5 6/6 3/3 4/4 4.5/4.5 5/5 6/6 3/3 4/4 4.5/4.5 5/5 6/6
SIM OR
NON-SIM
30
✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
40
✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
50
✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
66
✓ ✓ ✓ ✓
80
✓ ✓ ✓ ✓
120
✓ ✓ ✓ ✓
Electric Light Duty models are available with terminal block in both fused and non-fused configurations.
Fused configuration is Standard in all water heaters with power requirements over 48 Amps.
• Fused or Non-Fused, Fused if > 48 Amps • Terminal Block allows for conversions from Simultaneous element usage to non-Simultaneous for maximum energy savings.
• ELD-C Models 66/80/120 still available without terminal block. • All models are factory shipped with sim configuration.
ELECTRICAL CHARACTERISTICS
ELEMENT
WATTAGE
ELEMENT
WATTAGE
NON-SIMULTANEOUS WIRING SIMULTANEOUS WIRING
SINGLE/THREE PHASE OPERATION
FULL LOAD CURRENT IN AMPERES
2-WIRE SINGLE PHASE OPERATION
FULL LOAD CURRENT IN AMPERES
4-WIRE THREE PHASE
OPERATION FULL LOAD
CURRENT IN AMPERES
4-WIRE SINGLE PHASE OPERATION
FULL LOAD CURRENT IN AMPERES
(DOUBLE BRANCH CIRCUIT)
UPPER LOWER
TERMINALS L1 AND L2 FOR
SINGLE PHASE,
L1, L2, AND T2 FOR 3 PHASE
TERMINALS L1 AND L2
THERE'S NO 4 WIRE 3 PHASE
THIS IS 3 PHASE SIM
TERMINALS L1, L2, AND T2
TERMINALS L1 AND L2 FIRST CIRCUIT
TERMINALS T1 AND T2
SECOND CIRCUIT
208 240 277 480 208 240 277 480 208 240 480 208 240 277 480
3000 3000 14 13 11 6 29 25 22 13 25 22 11
SAME AS NON SIM,
BUT THERE WILL BE TWO
SETS OF INCOMING POWER.
THIS IS THE FACTORY WIRING
4000 4000 19 17 14 8 38 33 29 17 33 29 14
4500 4500 22 19 16 9 43 38 32 19 37 32 16
5000 5000 24 21 18 10 48 42 36 21 42 36 18
6000 6000 29 25 22 13 58 50 43 25 50 43 22
6050 6050 29 25 22 13 58 50 44 25 50 44 22
Consult factory for certification requirements.