Instructions / Assembly

46
Before You Call For Service…
Alarm (‘A’)
and Alert
(‘T’) Codes
Description Current Alarm Screen Display
T128
Anode “open” circuit. This can be caused by
wiring damage, wiring disconnected, or anode
damage.
T128 Middle Anode Open
->Check wiring connections for the middle
anode. If error persists, please contact technical
support or service provider.
T129
Anode control common and the power connec-
tion for this anode cross connected.
T129 Middle Anode Mounting Error
->Check wiring connections for the middle
anode. If error persists, please contact technical
support or service provider.
T130
Anode “short” circuited. This can be caused by
wiring damage, anode damage, or the anode in
contact with the tank.
T130 Middle Anode Shorted
->Check wiring connections for the middle
anode. If error persists, please contact technical
support or service provider.
T131
Anode power = 100%. The anode system has
reached its protective limits on one or more
anode elements.
T131 Middle Anode Overload
->Middle Anode has reached full capacity.
Tank may not be fully protected. Contact techni-
cal support or service provider.
T132
Anode power > 70%. The anode system is ap-
proaching its protective limits on one or more
anode elements.
T132 Middle Anode Pre-Overload
->Middle Anode near end of useful life but
will continue protecting tank. Please contact
technical support.
T133
Anode “open” circuit. This can be caused by
wiring damage, wiring disconnected, or anode
damage.
T133 Lower Anode Open
->Check wiring connections for the upper
anode. If error persists, please contact technical
support or service provider.
T134
Anode control common and the power connec-
tion for this anode cross connected.
T134 Lower Anode Mounting Error
->Check wiring connections for the lower
anode. If error persists, please contact technical
support or service provider.
T135
Anode “short” circuited. This can be caused by
wiring damage, anode damage, or the anode in
contact with the tank.
T135 Lower Anode Shorted
->Check wiring connections for the lower
anode. If error persists, please contact technical
support or service provider.
T136
Anode power = 100%. The anode system has
reached its protective limits on one or more
anode elements.
T136 Lower Anode Overload
->Lower Anode has reached full capacity.
Tank may not be fully protected. Contact techni-
cal support or service provider.
T137
Anode power > 70%. The anode system is ap-
proaching its protective limits on one or more
anode elements.
T137 Lower Anode Pre-Overload
->Lower Anode near end of useful life but will
continue protecting tank. Please contact techni-
cal support.