Instructions / Assembly

8
Failure to properly vent the water heater to the outdoors as out-
lined above and in the following section can result in unsafe opera-
tion of the water heater causing bodily injury, explosion, fire or
death.
NOTICE: DO NOT use in conjunction with a GFCI.
To
avoid the risk of fire, explosion or asphyxiation from carbon
monoxide, NEVER operate this water heater unless it is properly
vented and has an adequate air supply for proper operation. It
is important that the vent pipe engages fully into any pipe fitting
and be kept in that position until the adhesive has fully cured.
DO NOT drill or punch holes in the plastic pipe or fittings.
7. VENTING —
NOTE: This unit can be vented either as a direct vent
or power vent configuration.
NOTICE: This unit can be vented using only the below
recommended pipe material. Use only 2, 3, 4, or 6
inch diameter pipe.
Refer to local codes for restrictions on the use of PVC,
CPVC, PP or ABS pipe and fittings. All exhaust venting
materials for products installed in Canada must meet
ULC-S636.
PVC (Schedule 40, ASTM D-1785)
CPVC (Schedule 40, ASTM F-441)
ABS (Schedule 40, ASTM D-2661)(Not permitted in
Canada)
PVC Cellular Core (Schedule 40, ASTM F-891)(Not
permitted in Canada)
The fittings, other than the VENT TERMINAL,
should be equivalent to the following:
PVC (Schedule 40 DWV, ASTM D-2665)
Installation
Figure 3. — Typical Installation Drawing.
NOTES:
The gas supply piping must be adequately supported and aligned to
minimize loads (forces) on the water heater’s gas valve and burner
system.
Vacuum Relief Valve
(Not Supplied)
If required, install per local codes
and valve manufacturer’s
instructions.
Temperature &
Pressure Relief
Valve
Air Gap 6"
Hot Outlet
Cold Water
Inlet
Thermal Expansion Tank
(Not Supplied)
If required, install per local codes and
tank manufacturer's instructions.
Shut -Off Valve
To Gas Supply
Manual Gas Shut Off
Gas Pipe to Gas Valve
Sediment Trap
Discharge Line to
suitable open drain
WA RNING
!
WA RNING
!
Vacuum Relief Valve
(Not Supplied)
If required, install per local codes and
valve manufacturer's instructions.