Specifications

TM040 16, 18 & 20L Continuous Flow Gas Water Heater Service Instructions
D.O.I: 2/06/2009
This document is stored and maintained electronically by Service. All printed copies not bearing this statement in RED are deemed “uncontrolled”
25
Diagnostic Test Points
Refer to wiring diagram on page 6 for connector and wiring positions.
Test
Point
Measuring Point
Normal Condition
Items Under Test
Connector
Wire Nº
& colour
1
H & I
R R
AC 90V 110V
Main Power
2
T
W1 W2
50 kilo-ohms 500 kilo-ohms
Overheat Limiter
3
R
BR1 BK2
DC 2V 5V(Pulse) *
Water Flow Sensor pulse signal
More than 1310 pulse/min
R3 BK2
DC 11V 17V
Water Flow Sensor
4
F
B4 W6
DC 120V 160V
Fan Motor
R3 B4
DC 12V 18V
Y1 B4
DC 4V 10V(Pulse) *
Fan Motor pulse signal
More than 4800 pulse/min
5
Q
W6 BK3
@ 20ºC 10.3 kilo-ohms
Water Inlet Thermistor
@ 40ºC 4.9 kilo-ohms
6
Q
Y5 BK3
@ 20ºC 10.3 kilo-ohms
Heat Exchanger Thermistor
@ 40ºC 4.9 kilo-ohms
7
Q
R4 BK3
@ 20ºC 10.3 kilo-ohms
Hot Water Outlet Thermistor
@ 40ºC 4.9 kilo-ohms
8
L & J
W1 Earth
AC 3V 20V **
Flame Sensor not detecting flame
K & J
R1 Earth
AC 3V 20V **
9
Q
R1 BK2
DC 1.5V 14.0V
Proportional Gas Flow R. V
40 ohms 80 ohms
10
J
Y1 BK5
DC 75V 100V
Gas Inlet Solenoid Valve
0.8 kilo-ohms 2.2 kilo-ohms
11
G
GY2 GY5
AC 90V 110V
Igniter
12
J
W2 BK5
DC 75V 100V
Solenoid Valve 1
0.8 kilo-ohms 2.2 kilo-ohms
13
J
R3 BK5
DC 75V 100V
Solenoid Valve 2
0.8 kilo-ohms 2.2 kilo-ohms
14
L & J
W1 Earth
AC 1V 100V **
Flame Sensor detecting flame.
K & J
R1 Earth
AC 1V 100V **
15
B
W2 BK8
DC 8V 16V
Water Volume Control Motor position
switch
R7 BK8
DC 8V 16V
GR6 BK8
Less than DC 1V (Limiter on)
DC 4V 6V (Limiter off)
16
Q
B7 BK3
@ 20ºC 10.3 kilo-ohms
@ 40ºC 4.9 kilo-ohms
Ambient Air Thermistor
NOTES:
* : Approximate reading measured by digital multimeter on DC range.
** : Approximate reading measured by digital multimeter on AC range.