TM040 16, 18 & 20L Continuous Flow Gas Water Heater Service Instructions
D.O.I: 2/06/2009
This document is stored and maintained electronically by Service. All printed copies not bearing this statement in RED are deemed “uncontrolled”
31
Fault Finding Tests 1 – 3
Components will be “Live” when conducting tests, exercise caution.
Test 1
Power Filter
Using a multimeter set on the AC volts scale, measure the voltage at the connector plug to the
transformer primary winding.
Normal voltage is between 230V and 250V.
Test 2
Test 3
OMRON
G5NB-1A4
12VDC JAPAN
12VDC JAPAN
G5NB-1A4
OMRON
OMRON
G5NB-1A4
12VDC JAPAN
H
I
D
C
Using a multimeter set on the AC volts scale,
measure the voltage between red wires at
terminals H & I on the PCB.
Normal voltage is between 90V and 110V.
Using a multimeter set on the DC volts scale,
measure the voltage between terminals C &
D on the PCB.
Normal voltage is 12V.