Specifications

TM040 16, 18 & 20L Continuous Flow Gas Water Heater Service Instructions
D.O.I: 2/06/2009
This document is stored and maintained electronically by Service. All printed copies not bearing this statement in RED are deemed “uncontrolled”
55
Power Filter
1. Remove the PCB Assembly. Refer to „PCB Assembly‟ procedure on page 48.
2. Disconnect the incoming and outgoing Power Filter wiring loom plugs.
Note: Some wiring retainers will need to be released to allow wiring to be removed.
3. Remove the two screws retaining the Power Filter to the mounting bracket on the Fan
Assembly.
4. Remove the Power Filter. Note: An earth wire is connected to the power filter mounting
bracket. Ensure it is reconnected when the Power Filter is refitted.
5. Reassemble in reverse order of above.