TM040 16, 18 & 20L Continuous Flow Gas Water Heater Service Instructions
D.O.I: 2/06/2009
This document is stored and maintained electronically by Service. All printed copies not bearing this statement in RED are deemed “uncontrolled”
7
Preset Temperature Adjustment
Factory pre-set and maximum hot water outlet temperature settings for each water heater
series are shown below:
Model
Factory setting
Maximum Temp
Solar Compatible
244, 274, 874 Series
60ºC
60ºC
Y
246, 276, 876 Series
48ºC
48ºC
N
Voltages up to 240 volts will be present within the water heater, take care
not to touch wiring terminals. Use an insulated tool when operating the DIP
switch or MIN and MAX buttons.
To adjust the preset temperature:
1. Remove the front cover from the water heater.
2. Turn DIP switches 3 and 4 ON (up position) on the PCB.
3. The temperature setting will be displayed by a series of flashes from the red LED, with
a three (3) second pause between each series of flashes. The temperature settings
and series of flashes are:
Preset Temperature Settings
Flashes
244, 274 874 series
246, 276, 876 series
Minimum temperature setting
1 flash
50°C
40°C
Mid temperature setting
2 flashes
55°C
43°C
Maximum temperature setting
3 flashes
60°C
48°C
4. Press the MIN or MAX button, located above the DIP Switches, until the desired
temperature is reached (indicated by the number of flashes from the red LED).
5. Turn DIP SWITCHES 3 and 4 off (down position).
6. The red LED will go out. The preset outlet temperature is now set.
7. Refit the front cover to the water heater.