Sales Fact Sheet
SALES FACT SHEET
Rheem Heating, Cooling and Water Heating FORM NO. P11-780-SFS REV. 3
P.O. Box 17010, Fort Smith, AR 72917 PRINTED IN U.S.A. DC 10-11
R P Q L — 0 018
COOLING
CAPACITY
018 = 18,000 BTU/HR [5.28 kW]
024 = 24,000 BTU/HR [7.03 kW]
030 = 30,000 BTU/HR [8.79 kW]
036/037 = 36,000 BTU/HR [10.55 kW]
042 = 42,000 BTU/HR [12.31 kW]
048 = 48,000 BTU/HR [14.07 kW]
056 = 56,000 BTU/HR [16.41 kW]
060 = 60,000 BTU/HR [17.58 kW]
J E Z
RHEEM REMOTE
HEAT PUMP
Q = 15 SEER DESIGN
SERIES
L = R-410A
ELECTRICAL
DESIGNATION
J = 208/230V-1-60
VARIATIONS
E = EQUIPPED WITH
THE
COMFORT
CONTROL SYSTEM
™
COOLING
CONNECTION
FITTING
Z = SWEAT
W/SCROLL
Starting at:
Price $
Features
The Rheem
Prestige Series
®
RPQL -JEZ Heat Pump Outdoor units
can provide year-round heating and cooling comfort for residential,
multi-family and light commercial applications. They are designed to
operate with Rheem indoor units with cooling and heating capaci-
ties certified under the AHRI Certification program.
■
The
Comfort Control System
™
provides on-board diagnostics and
fault history for heat pumps with single-phase compressors by
detecting system and electrical problems without adding sensors.
It can also communicate “fault codes” to enabled “L terminal” ther-
mostats. The integrated diagnostics with
Active Protection
pre-
vents compressor operation when potentially harmful conditions
are detected.
■
7-Segment LED Display is exclusive only to Rheem products. The
information-display quickly and accurately shows technicians the
source of malfunctions.
■
Five-year conditional unit replacement warranty.
■
Attractive, louvered wrap around jacket protects coil from weather
extremes and yard hazards. Top grille is steel reinforced for extra
strength. Cabinet is powder painted for all weather protection.
■
Four sided outdoor coil design allows compressor operation with
access panel removed.
■
Air is discharged upward away from bushes and shrubs. The dis-
charge pattern of the top grille provides minimum air restriction,
resulting in quiet fan operation.
■
Combination Grille/Motor Mount secures the fan motor to the
underside of the discharge grille. The grille protects the motor
windings and bearings from rain and snow.
■
Removable top grille provides access to the outdoor fan motor
and outdoor coil.
■
Compressor compartment offers additional protection from the
elements and reduces operating noise.
■
Single speed, 8-pole fan motor is designed for low speed, quieter,
energy-saving operation.
■
Non-cycling reversing valve and demand defrost.
■
All models meet or exceed a 1000-hour salt spray test per ASTM
B117 Standard Practice for Operating Salt Spray Testing Apparatus.
GENERAL TERMS OF LIMITED WARRANTY
Rheem will furnish a replacement for any part of this product which fails in
normal use and service within the applicable period stated, in accordance
with the terms of the limited warranty.
Compressor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Ten (10) Years
Any Other Part . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Ten (10) Years
RPQL- JEZ Conditional Replacement Warranty:
Rheem will provide a replacement model (if an exact replacement is not
available, an equivalent product will be provided) to the original purchaser if
the compressor fails within 5 years (providing the unit is installed with a new
Rheem Air Handler OR Rheem Indoor Coil with a Rheem Gas Furnace, and
is properly matched as specified by Rheem as listed in the Air Condi tioning
Institute (AHRI) published rating, and if additional conditions are satisfied.
See product warranty card for additional information.
Equipped with
the Award Winning
Comfort Control System
™
• Increased Reliability • Fault Recall
• On-Board Diagnostics •
Active Protection
™
RPQL- JEZ 15 SEER MODELS
Seven Models
Efficiencies up to 15.5 SEER/13 EER/
10.45 HSPF
“Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with
appropriate coil components to meet ENERGY STAR criteria. Ask your Contractor for details or visit www.energystar.gov.”
[ ] Designates Metric Conversions