Specification Sheet

PRINTED IN U.S.A. 01/14 WP FORM NO. PRO+G RHPDVCAN
INTEGRATED HOME COMFOR
T
INTEGRATED HOME COMFORT
Professional Classic Plus
Power Direct Vent gas
water heaters are a perfect choice for tight
construction or when indoor air quality is a concern
Efficiency
• 0 .62 - 0.67** EF
Performance
FHR: Up to 139 gallons for natural
and LP gas
Recovery: 40 to 75.8 at a
90 degree rise
Self-Diagnostic System
Electronic gas control for
improved monitoring and
service
Low Emissions
Eco-friendly burner, low NOx design
Features
Two pipe system: one pipe pulls in
outside air for combustion and the
other exhausts combustion gases
120 VAC powered blower
New whisper quiet blower
Flammable Vapor
Detection System
Protective control system that
disables the heater in the presence of
ammable vapor accumulation
Flexible Venting Options
Long venting lengths up to 100 feet
PVC or CPVC certied to ULC-S636
vent pipe options
• Vertical or horizontal termination
• Concentric vent kit available
Longer Life
Rheem exclusive R-Tech (resistored)
anode rod provides long-lasting tank
protection
High Altitude Compliant
Models are certied for applications up
to 10,200 feet above sea level
Plus…
Enhanced ow brass drain valve
Temperature and pressure relief valve
included
• Low lead compliant
Durable silicon nitride igniter (HSI)
Side taps for space heating
applications on 50-65, 65 and
75-gallon models
EverKleen
patented system ghts
sediment build-up
Standard replacement parts
Warranty
8-Year limited tank and parts
warranty*
With ProtectionPlus
the 8-year limited
tank warranty becomes 10-year
ProtectionPlus – order part number
SP20081 (6 pack only)
* See Residential Warranty Certicate for
complete information
Professional Classic Plus
Power Direct Vent
40 to 75-Gallon Capacities
Up to 75,100 Btu/h
Natural and LP Gas
Water
INTEGRATED HOME COMFORT
Residential Gas
Professional Classic Plus
Power Direct Vent Water Heaters
See venting chart on back.
LEED Point = 1
D
C
G
B A
E
T&P FITTING
3/4" N.P.T.
1/2"
HOT
WATER
CONNECTION
COMBUSTION
EXHAUST
(VENT)
COMBUSTION
AIR INLET
H
COLD
WATER
CONNECTION
H
F
I
DESCRIPTION FEATURES ROUGHING IN DIMENSIONS (SHOWN IN INCHES) ENERGY INFO.
T HT. TO HT. TO HT. TO WATER HT. TO WATER FRONT AVG.
Y NATURAL GAS
GAS INPUT IN RECOVERY IN FIRST HOUR
TOP OF TOP OF TANK GAS CONN. SIDE T&P CONN. TO SHIP.
ENERGY
ANNUAL
P GAL. MODEL
THOUS. BTU/H G.P.H. 90° RISE DEL. G.P.H.
VENT AIR INLET HT. DIAM. CONN. CNTR. VALVE SIZE BACK WT.
FACTOR
OPER. COST
E CAP. NUMBER NAT. LP NAT. LP NAT. LP A B C D E F G H I (LBS) NAT. LP NAT
Tall 40 PRO+G40T-40N CN67 PDV** 40 38 40.4 38.4 73 73 68-1/2 69-1/4 60-1/4 19-3/4 14 8 53-3/4 3/4 29-1/2 180 0.67 0.67 $272
Tall 50 PRO+G50T-40N CN67 PDV** 40 40 40.4 40.4 93 93 67-5/8 67-7/8 59-3/8 21-3/4 14 8 52-3/4 3/4 31-1/2 205 0.67 0.67 $272
Tall 50 PRO+G50T-65N CN62 PDV 65 47 65.7 47.5 111 92 67-5/8 68-3/8 59-3/8 21-3/4 14 8 52-3/4 3/4 31-1/2 210 0.62 0.62 $294
Tall 65 PRO+G65T-65N CN62 PDV 65 56 65.7 56.6 120 113 71-1/4 72-1/4 61-3/4 23 14-5/8 11 54 3/4 34-1/4 285 0.62 0.62 $294
Tall 75 PRO+G75T-75N CN62 PDV 75.1 70 75.8 70.7 139 139 70-3/8 71-1/4 60-1/2 26-1/4 15 11 53 1 36-3/4 325 0.62 0.62 $495†
Specify LP gas when ordering. Add gas input and "P" to model number. Example: PRO+G40T-38P CN67 PDV
**ENERGY STAR
®
qualified models.

Summary of content (2 pages)