Air Air Conditioners RA13 Series Rheem Classic® Series Air Conditioners RA13 Series Efficiencies 13-15.5 SEER/11.5-13 EER Nominal Sizes 11/2 to 5 Ton [5.28 to 17.6 kW] Cooling Capacities 17.3 to 60.5 kBTU [5.7 to 17.7 kW] 15.5 “Proper sizing and installation of equipment is critical to achieve optimal performance. Ask your Dealer for details or visit www.energystar.gov.
Air Table of Contents RA13 Series TABLE OF CONTENTS Standard Feature ......................................................................................................3 Available SKUs ........................................................................................................3 Features & Benefits ..............................................................................................4-5 Model Number Identification ......................................................................
Air Standard Feature/Available SKUs RA13 Series Standard Feature Table STANDARD FEATURES Feature R-410a Refrigerant Maximum SEER Maximum EER Scroll Compressor Field Installed Filter Drier Front Seating Service Valves Internal Pressure Relief Valve Internal Thermal Overload Long Line capability Low Ambient capability with Kit 3-4-5 Expanded Valve Space Composite Basepan 2 Screw Control Box Access 15" Access to Internal Components Quick release louver panel design No fasteners to remove along bottom Optimiz
Air Features & Benefits RA13 Series Introduction to RA13 Air Conditioner The RA13 is our 13 SEER air conditioner and is part of the Rheem air conditioner product line that extends from 13 to 20 SEER. This highly featured and reliable air conditioner is designed for years of reliable, efficient operation when matched with Rheem indoor aluminum evaporator coils and furnaces or air handler units with aluminum evaporators.
Air The entire cabinet has powder post paint ( 20 ) achieving 1000 hour salt spray rating, allowing the cabinet to retain its aesthetics throughout its life.
A 13 Product Category P - Heat Pump Brand 13 - 13 SEER 14 - 14 SEER 15 - 15 SEER 17 - 17 SEER 20 - 20 SEER SEER 14 Product Category C - Evap Coil Brand F - Furn Coil H - Air-Handler Coil Type F [ ] Designates Metric Conversions Rheem C R Furnace Coils (For Reference) Rheem P R Heat Pumps (For Reference) A J 1 N A * 24 Capacity BTU/HR 18 - 18,000 [5.28 kW] 24 - 24,000 [7.03 kW] 30 - 30,000 [8.79 kW] 36 - 36,000 [10.55 kW] 42 - 42,000 [12.31 kW] 48 - 48,000 [14.
V - Variable speed T - Constant Torque (X-13) P - PSC 90 - 90 AFUE 92 - 92 AFUE 95 - 95 AFUE 96 - 96 AFUE 97 - 97 AFUE Rheem A - 1st Design Major Rev A 1 - Single-stage 2 - Two-stage 80 - 80+ AFUE Rheem H T Motor V Capacity BTU/HR 24 - 24,000 [7.03 kW] 36 - 36,000 [10.55 kW] 48 - 48,000 [14.07 kW] 60 - 60,000 [17.58 kW] 36 70 Stages 2 Coil Size S - Standard Eff. M -Mid Eff. H - High Eff. 14 - 14" 17 - 17.5" 21 - 21" 24 - 24.
Air General Data/Electrical Data RA13 Series Physical Data Model No. Nominal Tonnage Valve Connections Liquid Line O.D. – in. Suction Line O.D. – in. Refrigerant (R410A) furnished oz.¹ Compressor Type Outdoor Coil Net face area – Outer Coil Net face area – Inner Coil Tube diameter – in. Number of rows Fins per inch Outdoor Fan Diameter – in. Number of blades Motor hp CFM RPM watts Shipping weight – lbs. Operating weight – lbs. RA1318A 1.5 PHYSICAL DATA RA1324A RA1330A 2.0 2.5 RA1336A 3.0 RA1342A 3.
Accessories/Weighted Sound Power/Thermostats RA13 Series Air Accessories Model No.
Air Unit Dimensions RA13 Series Unit Dimensions OPERATING MODEL NO. H (Height) L (Length) SHIPPING W (Width) H (Height) L (Length) W (Width) INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm RA1318 27 685 29.75 755 29.75 755 28.75 730 32.38 822 32.38 822 RA1324 25 635 29.75 755 29.75 755 26.75 679 32.38 822 32.38 822 RA1330 25 635 29.75 755 29.75 755 26.75 679 32.38 822 32.38 822 RA1336 27 685 29.75 755 29.75 755 28.75 730 32.
24⬙ (609.6) Service 6⬙ (152.4) 24⬙ (609.6) 24⬙ recommended 9⬙ minimum 12⬙ (304.8) 6⬙ (152.4) 24⬙ (609.6) Service WALL 12⬙ (304.8) 24⬙ (609.6) 24⬙ recommended 9⬙ minimum IMPORTANT: When installing multiple units in an alcove, roof well or partially enclosed area, ensure there is adequate ventillation to prevent re-circulation of discharge air. NOTE: NUMBERS IN () = mm 18⬙ (457.2) 24⬙ (609.6) Service WALL CLEARANCES WALL 24⬙ (609.6) Service 12⬙ (304.8) 24⬙ (609.
Air Wiring Diagram/Application Guidelines RA13 Series Control Wiring FIGURE 2 *IF MAXIMUM OUTLET TEMPERATURE RISE IS DESIRED, IT IS RECOMMENDED THAT CONTROL WIRING FOR GAS OR OIL FURNACE W1 (W/BK) AND W2 (W/BL) BE JUMPERED TOGETHER.
Liquid Line Size Elevation (Above or Below) Indoor Coil Total Equivalent Length - Feet [m] 3/8" [9.53] 3/8" [9.53] 3/8" [9.53] 3/8" [9.53] 3/8" [9.53] 3/8" [9.53] 24 30 36 42 48 60 N/R 25 [7.62] 50 [15.24] 75 [22.86] 5/16 [7.94] N/R N/R N/R N/R 25 [7.62] 45 [13.72] 40 [12.19] 25 [7.62] 50 [15.24] 45 [13.72] 7/16 [11.12] 1/2 [12.71] [6.1] 25 [7.62] 30 [9.14] 20 N/R N/R 3/8 [9.53] 20 [6.1] 5/16 [7.94] N/R N/R 25 [7.62] 50 [15.24] 75 [22.86] 1/2 [12.71] N/R 25 [7.62] 50 [15.
3/4" [19.06] 3/4" [19.06] 3/4" [19.06] 7/8" [22.23] 7/8" [22.23] 7/8" [22.23] 24 30 36 42 48 60 NOTES: N/R = Application not recommended. All calculations assume a 3/8" liquid line 3/4" [19.06] 18 R-410A System Capacity Model 1.00 N/R N/R N/R 0.99 1.00 1.00 N/R N/R 0.99 1.00 N/R N/R N/R 1.00 1.00 1.00 N/R N/R 1.00 3/4 [19.05] 7/8 [22.23] 1 [25.4] 1-1/8 [28.58] 5/8 [15.88] 3/4 [19.05] 1 [25.4] 1-1/8 [28.58] 5/8 [15.88] 3/4 [19.05] 1.00 1.00 0.99 1.00 1.00 1.00 1.00 0.99 1.00 1.00 1.
Air Performance Data RA13 Series Performance Data @ AHRI Standard Conditions – Cooling High Sales Volume Tested Combination (HSVTC) Outdoor Unit Indoor Coil Total Capacity BTU/H [kW] Net Sensible BTU/H [kW] Net Latent BTU/H [kW] SEER EER Indoor CFM [L/s] AHRI# RA1318AJ1 RCF2417STAM 17600 [5.2] 13100 [3.8] 4500 [1.3] 13 11 600 [283.2] 7507439 RA1324AJ1 RCF2417STAM 23600 [6.9] 17600 [5.2] 6000 [1.8] 13 11 800 [377.6] 7507649 RA1330AJ1 RCF3617STAM 28400 [8.3] 21600 [6.
Air Performance Data RA13 Series Performance Data @ AHRI Standard Conditions – Cooling (con’t.
Air Performance Data RA13 Series Performance Data @ AHRI Standard Conditions – Cooling (con’t.
Air Performance Data RA13 Series Performance Data @ AHRI Standard Conditions – Cooling (con’t.) R801T Furnace Ratings Outdoor Unit Furnace RA1342AC1 R801TA125524ZSA RA1342AJ1 RA1342AJ1 RA1342AJ1 RA1342AJ1 RA1342AJ1 RA1342AJ1 Indoor Coil Total Capacity BTU/H [kW] Net Sensible BTU/H [kW] Net Latent BTU/H [kW] SEER EER RCF4824HTAM 41500 [12.2] 28100 [8.2] 13400 [3.9] 14.5 RCF4824STAM 39500 [11.6] 27700 [8.1] 11800 [3.5] 14 R801TA075317ZSA RCF4821STAM 40000 [11.7] 29000 [8.
Air Performance Data RA13 Series Performance Data @ AHRI Standard Conditions – Cooling (con’t.
Air Performance Data RA13 Series Performance Data @ AHRI Standard Conditions – Cooling (con’t.
Air Performance Data RA13 Series Performance Data @ AHRI Standard Conditions – Cooling (con’t.) R95T Furnace Ratings Outdoor Unit Furnace Indoor Coil Total Capacity BTU/H [kW] Net Sensible BTU/H [kW] Net Latent BTU/H [kW] SEER EER Indoor CFM [L/s] AHRI# RA1342AC1 R95TA0601317MSA RCF4821STAM 39000 [11.4] 26900 [7.9] 12100 [3.5] 13.5 11.5 1050 [495.5] 7511565 RA1342AC1 R95TA0701317MSA RCF4821STAM 39000 [11.4] 27300 [8.0] 11700 [3.4] 13 11.5 1125 [530.
Air Performance Data RA13 Series Performance Data @ AHRI Standard Conditions – Cooling (con’t.) RGFG Furnace Ratings Outdoor Unit RA1318AJ1 Furnace RGFG-06?MCK? Indoor Coil Total Capacity BTU/H [kW] Net Sensible BTU/H [kW] Net Latent BTU/H [kW] SEER EER Indoor CFM [L/s] AHRI# RCF2417HTAM 18000 [5.3] 12800 [3.8] 5200 [1.5] 14.5 12 575 [271.4] 7507412 RCF2417MTAM 18000 [5.3] 12800 [3.8] 5200 [1.5] 14.5 12 575 [271.4] 7507427 RCF2417STAM 17900 [5.2] 13400 [3.9] 4500 [1.3] 14.
Air Performance Data RA13 Series Performance Data @ AHRI Standard Conditions – Cooling (con’t.
Air Performance Data RA13 Series Performance Data @ AHRI Standard Conditions – Cooling (con’t.) RGFG Furnace Ratings Outdoor Unit Furnace Indoor Coil Total Capacity BTU/H [kW] Net Sensible BTU/H [kW] Net Latent BTU/H [kW] SEER EER Indoor CFM [L/s] AHRI# RA1348AJ1 RGFG-10?ZCM? RCF4824HTAM 49000 [14.4] 33000 [9.7] 16000 [4.7] 13 11.5 1400 [660.7] 7509173 RCF4824HTAM 49500 [14.5] 33800 [9.9] 15700 [4.6] 13.5 11.5 1450 [684.3] 7509174 RCF4824STAM 46500 [13.6] 31600 [9.
Air Performance Data RA13 Series Performance Data @ AHRI Standard Conditions – Cooling (con’t.) RGJF Furnace Ratings Outdoor Unit RA1318AJ1 Furnace RGJF-06?MCK? Indoor Coil Total Capacity BTU/H [kW] Net Sensible BTU/H [kW] Net Latent BTU/H [kW] SEER EER Indoor CFM [L/s] AHRI# RCF2417HTAM 18000 [5.3] 12800 [3.8] 5200 [1.5] 14.5 12 625 [295.0] 7507414 RCF2417MTAM 18000 [5.3] 12800 [3.8] 5200 [1.5] 14.5 12 625 [295.0] 7507429 RCF2417STAM 18000 [5.3] 13500 [4.0] 4500 [1.3] 14.
Air Performance Data RA13 Series Performance Data @ AHRI Standard Conditions – Cooling (con’t.) RGJF Furnace Ratings Outdoor Unit RA1336AC1 RA1336AC1 RA1336AJ1 RA1336AJ1 RA1336AJ1 RA1336AJ1 Furnace RGJF-10?ZCM? RGJF-12?RCM? RGJF-06?MCK? RGJF-07?MCK? RGJF-09?ZCM? RGJF-10?ZCM? Indoor Coil Total Capacity BTU/H [kW] Net Sensible BTU/H [kW] Net Latent BTU/H [kW] SEER EER Indoor CFM [L/s] AHRI# RCF3621MTAM 37200 [10.9] 25300 [7.4] 11900 [3.5] 14.5 RCF3621STAM 35000 [10.3] 25000 [7.
Air Performance Data RA13 Series Performance Data @ AHRI Standard Conditions – Cooling (con’t.
Air Performance Data RA13 Series Performance Data @ AHRI Standard Conditions – Cooling (con’t.) RGPE Furnace Ratings Outdoor Unit RA1318AJ1 RA1318AJ1 RA1324AJ1 RA1324AJ1 Furnace RGPE-05?BMK? RGPE-07?AMK? RGPE-05?BMK? RGPE-07?AMK? Indoor Coil Total Capacity BTU/H [kW] Net Sensible BTU/H [kW] Net Latent BTU/H [kW] SEER EER Indoor CFM [L/s] AHRI# RCF2417HTAM 18000 [5.3] 12800 [3.8] 5200 [1.5] 14.5 12 575 [271.4] 7507416 RCF2417MTAM 18000 [5.3] 12800 [3.8] 5200 [1.5] 14.
Air Performance Data RA13 Series Performance Data @ AHRI Standard Conditions – Cooling (con’t.) RGPE Furnace Ratings Outdoor Unit Furnace RA1336AC1 RGPE-12?ARM? RA1336AJ1 RA1336AJ1 RA1336AJ1 RA1336AJ1 RGPE-05?BMK? RGPE-07?AMK? RGPE-07?BRQ? RGPE-10?BRM? Indoor Coil Total Capacity BTU/H [kW] Net Sensible BTU/H [kW] Net Latent BTU/H [kW] SEER EER Indoor CFM [L/s] AHRI# RCF3624HTAM 39000 [11.4] 28000 [8.2] 11000 [3.2] 15.1 12.5 1200 [566.3] 7508290 RCF3624MTAM 38000 [11.
Air Performance Data RA13 Series Performance Data @ AHRI Standard Conditions – Cooling (con’t.
Air Performance Data RA13 Series Performance Data @ AHRI Standard Conditions – Cooling (con’t.
Air Performance Data RA13 Series Performance Data @ AHRI Standard Conditions – Cooling (con’t.) RGPT Furnace Ratings Outdoor Unit Furnace RA1336AJ1 RGPT-07?BRQ? RA1336AJ1 RGPT-10?BRM? Indoor Coil Total Capacity BTU/H [kW] Net Sensible BTU/H [kW] Net Latent BTU/H [kW] SEER EER Indoor CFM [L/s] AHRI# RCF3621MTAM 38500 [11.3] 27700 [8.1] 10800 [3.2] 14.5 12 RCF3621STAM 34800 [10.2] 24500 [7.2] 10300 [3.0] 14 11.5 1225 [578.1] 7508598 975 [460.1] RCF3624MTAM 38500 [11.
Air Performance Data RA13 Series Performance Data @ AHRI Standard Conditions – Cooling (con’t.) RGRM Furnace Ratings Outdoor Unit Furnace Indoor Coil Total Capacity BTU/H [kW] Net Sensible BTU/H [kW] Net Latent BTU/H [kW] SEER EER Indoor CFM [L/s] AHRI# RA1336AC1 RGRM-12?RAJ? RCF3624MTAM 37400 [11.0] 25900 [7.6] 11500 [3.4] 14.5 12 1075 [507.3] 7508317 RA1336AJ1 RGRM-12?RAJ? RCF3624MTAM 37400 [11.0] 25900 [7.6] 11500 [3.4] 14.5 12 1075 [507.
Air Performance Data RA13 Series Performance Data @ AHRI Standard Conditions – Cooling (con’t.
Air Performance Data RA13 Series Performance Data @ AHRI Standard Conditions – Cooling (con’t.) ROCA Furnace Ratings Outdoor Unit Furnace RA1342AC1 ROCA-070E03 RA1342AC1 RA1342AJ1 RA1342AJ1 ROCA-070E04 ROCA-070E03 ROCA-070E04 Indoor Coil Total Capacity BTU/H [kW] Net Sensible BTU/H [kW] Net Latent BTU/H [kW] SEER EER Indoor CFM [L/s] AHRI# RCF4821STAM 39500 [11.6] 28200 [8.3] 11300 [3.3] 13.5 11.5 1200 [566.3] 7511583 RCF4824HTAM 41500 [12.2] 28300 [8.3] 13200 [3.9] 14 11.
Air Performance Data RA13 Series Performance Data @ AHRI Standard Conditions – Cooling (con’t.
Air Performance Data RA13 Series Performance Data @ AHRI Standard Conditions – Cooling (con’t.
Air Performance Data RA13 Series Performance Data @ AHRI Standard Conditions – Cooling (con’t.) Air Handler Ratings Outdoor Unit RA1318AJ1 RA1324AJ1 RA1330AJ1 RA1336AC1 Total Capacity BTU/H [kW] Net Sensible BTU/H [kW] Net Latent BTU/H [kW] SEER EER Indoor CFM [L/s] AHRI# RBHP-17 17800 [5.2] 11800 [3.5] 6000 [1.8] 14 11.5 600 [283.2] 7507406 RH1P1817STAN 17700 [5.2] 13200 [3.9] 4500 [1.3] 13 11.5 600 [283.2] 7507603 RH1T2417STAN 18000 [5.3] 13500 [4.0] 4500 [1.3] 14.
Air Performance Data RA13 Series Performance Data @ AHRI Standard Conditions – Cooling (con’t.) Air Handler Ratings Outdoor Unit RA1336AJ1 RA1342AC1 RA1342AJ1 RA1348AC1 Total Capacity BTU/H [kW] Net Sensible BTU/H [kW] Net Latent BTU/H [kW] SEER EER Indoor CFM [L/s] AHRI# RBHP-21 36400 [10.7] 24500 [7.2] 11900 [3.5] 14 11.5 1200 [566.3] 7508556 RH1P3017STAN 34200 [10.0] 23800 [7.0] 10400 [3.0] 13 11 950 [448.4] 7508907 RH1T3617STAN 35200 [10.3] 24900 [7.3] 10300 [3.
Air Performance Data RA13 Series Performance Data @ AHRI Standard Conditions – Cooling (con’t.) Air Handler Ratings Outdoor Unit RA1348AC1 RA1348AJ1 RA1360AC1 RA1360AJ1 Air Handler Total Capacity BTU/H [kW] Net Sensible BTU/H [kW] Net Latent BTU/H [kW] SEER EER Indoor CFM [L/s] AHRI# RHKL-HM4824 47500 [13.9] 31500 [9.2] 16000 [4.7] 13 11.5 1625 [766.9] 7509138 RHKL-HM6024 51000 [14.9] 36100 [10.6] 14900 [4.4] 14.5 12 1600 [755.1] 7509139 RHPL-HM4824 47500 [13.9] 31500 [9.
Air Guide Specifications RA13 Series GUIDE SPECIFICATIONS General System Description Outdoor-mounted, air-cooled, split-system air conditioner composite base pan unit suitable for ground or rooftop installation. Unit consists of a hermetic compressor, an air-cooled coil, propeller-type condenser fan, suction and legend line service valve, and a control box. Unit will discharge supply air upward as shown on contract drawings. Unit will be used in a refrigeration circuit to match up to a coil unit.
Air Limited Warranty RA13 Series GENERAL TERMS OF LIMITED WARRANTY* Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty. *For complete details of the Limited and Conditional Warranties, including applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certificate.
Air Notes RA13 Series 43
The new degree of comfort.™ In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. Rheem Heating, Cooling & Water Heating • P.O. Box 17010 Fort Smith, Arkansas 72917 • www.rheem.com Rheem Canada Ltd./Ltée • 125 Edgeware Road, Unit 1 Brampton, Ontario • L6Y 0P5 PRINTED IN U.S.A. 3/15 QG FORM NO. A11-221 REV.