Use and Care Manual
45
Press this Button Less than 5 seconds
Change Heating set-point Temperature
100~180°F (38~82°C)
Hold this Button More than 5 seconds
Change DHW set-point Temperature
90~120°F (32~49°C) And DHW High
Temperature 121~140°F (49.4~60°C)
Indicator (Green)
Indicates Unit is Operating
Press this Button Less than 5 sec-
onds DHW Preheating Timer Setting
Hold this Button More than 5 seconds
Time, Day, Month, Year, Days of the
Week setting
Press this button less than 5 seconds: Cancel/Return to previous screen
Hold this button more than 5 seconds when control panel is ON: enter
Status Display Mode
Hold this button for more than
5 seconds when control panel
is OFF: enter Installer Mode
Press This Button Less than 5 Seconds
Turn Control Power Panel ON/OFF
Press this Button Less than 5 Seconds
Select Menu by Pressing Dial Button
Scroll Values by Turning Dial Clockwise(+) or
Counterclockwise(-)
Figure 28 – Appliance Control Panel Detail
Figure 27 – Terminal Block Wiring Detail
PART 10 – OPERATING SYSTEM INSTRUCTIONS
▪ A. CONTROL PANEL
AUTODESK � � � � � � � � � �
AUTODESK � � � � � � � � � �
AUTODESK � � � � � � � � � �
AUTODESK � � � � � � � � � �
Outdoor Temperature
Sensor
Heat Demand
(0-10V)
Connection
Outdoor Temperature Sensor Connection