Heat Pumps RP14AZ Endeavor™ Line Classic® Series iM Heat Pumps RP14AZ Cooling Efficiency: 14.3 SEER2 / 9.0 EER2 Heating Efficiency: 7.5 HSPF Nominal Sizes: 1.5 to 5 Tons [5.3 to 17.6 kW] Cooling & Heating Capacities: 17.1 kBTU to 55.5 kBTU FORM NO. P11-828 REV.
Table of Contents RP14AZ Table of Contents Features & Benefits ..................................................................3 Model Number Identification ....................................................4 General Data/Electrical Data ....................................................5 Accessories ..............................................................................6 Weighted Sound Power .......................................................... 6 Unit Dimensions .........................
Features and Benefits RP14AZ Features and Benefits • Swept Wing Fan Technology1: Features quieter operation and improved unit acoustics • Two-Stage Scroll Compressor2: Features two speeds (high and low) of cooling and heating, providing more precise temperature control, lower humidity and greater efficiency when compared to single stage compressors • PlusOne® Expanded Valve Space: 3 in. – 4 in. – 5 in.
Model Number Identification RP14AZ Heat Pumps R P 14 A Z 18 A J 1 N A Brand Product Category SEER2 Region Refrigerant Capacity Major Series Voltage Type Controls Minor Series 14 - 14.3 SEER2 A - All Regions Z - R-410A 18 - 18,000 [5.28 kW] 24 - 24,000 [7.03 kW] 30 - 30,000 [8.79 kW] 36 - 36,000 [10.55 kW] 42 - 42,000 [12.31 kW] 48 - 48,000 [14.07 kW] 60 - 60,000 [17.58 kW] A - 1st Design R - Rheem P - Heat Pump J - 208/230/1/60 1 - 1-Stage N - Non-Comm.
General Data/Electrical Data RP14AZ General Data MODEL NO. Nominal Tonnage Valve Connections Liquid Line O.D. – in. Suction Line O.D. – in. Refrigerant (R410A) furnished oz.¹ Compressor Type Outdoor Coil Net face area – Outer Coil Net face area – Inner Coil Tube diameter – in. Number of rows Fins per inch Outdoor Fan Diameter – in. Number of blades Motor hp CFM RPM watts Shipping weight – lbs. Operating weight – lbs.
Accessories/Weighted Sound Power RP14AZ Accessories MODEL NO.
Unit Dimensions RP14AZ Unit Dimensions OPERATING MODEL NO. H (Height) L (Length) SHIPPING W (Width) H (Height) L (Length) W (Width) INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm RP14AZ18**1 25.00 635 29.75 756 29.75 756 27.90 709 33.25 845 33.25 845 RP14AZ18**2 25.00 635 29.75 756 29.75 756 27.90 709 33.25 845 33.25 845 RP14AZ24 25.00 635 29.75 756 29.75 756 27.90 709 33.25 845 33.25 845 RP14AZ30 27.00 686 33.75 857 33.
Clearances RP14AZ 8 CLEARANCES WALL WALL 6 (152.4) 12 (304.8) WALL 24 (609.6) Service 24 (609.6) Service 12 (304.8) 6 (152.4) 6 (152.4) 12 (304.8) WALL 24 (609.6) Service 18 (457.2) 24 (609.6) Service 24 (609.6) 24 recommended 6 minimum 24 (609.6) Service 24 (609.
Control Wiring/Application Guidelines RP14AZ Control Wiring FIGURE 4 CONTROL WIRING FOR AIR HANDLER Heat Pump Thermostat B Y G W2 E C R TYPICAL THERMOSTAT: HEAT PUMP WITH ELECTRIC HEAT Air Handler W2 W/BL G G/BK Y Y W1 W/BK B BL ODD G/Y C BR R R Heat Pump Outdoor Unit Y B NOTES: 1. Jumper “E” to “W2” to transfer control of supplemental heat to 1st stage when the emergency heat switch is on. 2. This wire turns on heat for defrost, omit for most economical operation. 3.
Refrigerant Line Size Information RP14AZ Refrigerant Line Size Information SINGLE AND TWO-STAGE HEAT PUMPS UNIT SIZE MAX. LIQUID LINE SIZE SUCTION LINE SIZE OUTDOOR UNIT ABOVE OR BELOW INDOOR UNIT EQUIVALENT LENGTH IN FEET 0-15 16-25 26-50 51-80 81-100 101-125 126-150 MAXIMUM VERTICAL SEPARATION/CAPACITY MULTIPLIER 1.5 TON 2 TON 3/8" 3/8" 2.5 TON 3/8" 3 TON 3/8" 3.5 TON 4 TON 5 TON 3/8" 3/8" 3/8" 1/2" 15 / 1 25 / 1 50 / 0.99 80 / 0.97 100 / 0.97 115 / 0.96 115 / 0.
Refrigerant Line Size Information RP14AZ Refrigerant Line Size Information (Con’t.) SINGLE AND TWO-STAGE HEAT PUMPS UNIT SIZE MAX. LIQUID LINE SIZE SUCTION LINE SIZE OUTDOOR UNIT ABOVE OR BELOW INDOOR UNIT EQUIVALENT LENGTH IN METERS 0-5 5.5-8 8.5-15 15.5-24 24.5-30 30.5-38 38.5-46 MAXIMUM VERTICAL SEPARATION/CAPACITY MULTIPLIER 1.5 TON 2 TON 3/8" 3/8" 2.5 TON 3/8" 3 TON 3/8" 3.5 TON 3/8" 4 TON 3/8" 5 TON 3/8" 1/2" 5/1 8/1 15 / 0.99 24 / 0.97 30 / 0.97 35 / 0.96 35 / 0.
Performance Data RP14AZ Performance Data @ AHRI Standard Conditions – Cooling DESIGNATED TESTED COMBINATION (DTC) OUTDOOR UNIT AIR HANDLER TOTAL CAPACITY BTU/H [kW] NET NET SENSIBLE LATENT SEER2 EER2 BTU/H [kW] BTU/H [kW] INDOOR CFM [L/S] 47 DEGREE 17 DEGREE 47 17 REGION HEATING HEATING DEGREE DEGREE IV CAPACITY CAPACITY COP COP HSPF2 BTU/H [KW] BTU/H [KW] RP14AZ18AJ1 RH2TZ2417STANN 17100 [5.0] 13100 [3.8] 4000 [1.2] 14.3 9.0 575 [271.4] 17100 [5.0] 3.78 11100 [3.3] 2.56 7.
Notes RP14AZ 13
Notes RP14AZ 14
Notes RP14AZ 15
GENERAL TERMS OF LIMITED WARRANTY* Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty. Conditional Parts (Registration Required).................................