Instruction Manual

UNIT SIZE - VOLTAGE, SERIES
STANDARD
RATING (DBA)
TYPICAL OCTAVE BAND SPECTRUM (dBA without tone adjustment)
125 250 500 1000 2000 4000 8000
RP14AZ18A 73 39.8 55 62.1 67.0 60.0 57.4 51.2
RP14AZ24A 73 40.4 55.4 62.5 65.9 58.7 56.4 48.9
RP14AZ30A 72 48.9 55.3 63.6 61.0 59.1 56.5 48.7
RP14AZ36A 72 50.1 55.8 64.4 61.5 58.7 55.1 50.9
RP14AZ42A 72 48.6 56.2 63.1 61.7 60.0 56 50.0
RP14AZ48A 74 49.3 56 64.5 64.5 60.1 54.9 47.7
RP14AZ60A 74 43.9 55.2 63.4 65.8 61.7 57.9 52.9
6
Accessories/Weighted Sound Power
RP14AZ
Accessories
MODEL NO.
RP14AZ18**1 RP14AZ18**2 RP14AZ24 RP14AZ30 RP14AZ36 RP14AZ42 RP14AZ48 RP14AZ60
Compressor crankcase heater*
44-17402-44 44-17402-44 44-17402-44 44-17402-44 44-17402-44 44-17402-45 44-17402-45 Factory Standard
Low ambient control
RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08
Compressor sound cover
68-23427-26 68-23427-26 68-23427-26 68-23427-26 68-23427-26 68-23427-25 68-23427-25 68-23427-25
Compressor hard start kit
SK-A1 SK-A1 SK-A1 SK-A1 SK-A1 SK-A1 SK-A1 SK-A1
Low pressure control
Factory Standard Factory Standard Factory Standard Factory Standard Factory Standard Factory Standard Factory Standard Factory Standard
High pressure control
Factory Standard Factory Standard Factory Standard Factory Standard Factory Standard Factory Standard Factory Standard Factory Standard
Liquid Line Solenoid
(24 VAC, 50/60 Hz)
Solenoid Valve
200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD3T3TVLC 200RD3T3TVLC
Solenoid Coil
61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V
Liquid Line Solenoid
(120/240 VAC,
50/60 Hz)
Solenoid Valve
200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD3T3TVLC 200RD3T3TVLC
Solenoid Coil
61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V
Classic Top Cap w/Label
91-101123-21 91-101123-21 91-101123-21 91-101123-21 91-101123-21 91-101123-21 91-101123-21 91-101123-21
Weighted Sound Power Level (dBA)
NOTE: Tested in accordance with AHRI Standard 270-08 (not listed in AHRI)
*Bi-flow kits are required when installing a liquid line solenoid on a heat pump.