Specification Sheet

Rheem Classic
®
Series
Heat Pump
FORM NO. P11-807 REV. 1
RP15 Series
Efficiencies: 14-15 SEER/11.5-12.5 EER
Nominal Sizes 1
1
/2 to 5 Ton [5.28 to 17.6 kW]
Cooling Capacities 17.3 to 60.5 kBTU
[5.7 to 17.7 kW]
New composite base pan – dampens sound, captures louver
panels, eliminates corrosion and reduces number of fasteners
needed
Improved tubing design – reduces vibration and stress, mak-
ing unit quieter and reducing opportunity for leaks
Optimized defrost characteristics - decrease defrosting and
provide better home comfort
Powder coat paint system – for a long lasting professional finish
Optimized reversing valve sizing – improves shifting perfor-
mance for quieter unit operation and increased life of the
system
Enhanced mufflers – help to dissipate vibration energy for
quieter unit operation
Scroll compressor – a sound abating feature added to the
compressor significantly reduces noise when system transi-
tions in and out of defrost mode
Modern cabinet aesthetics – increased curb appeal with visu-
ally appealing design
Curved louver panels – provide ultimate coil protection,
enhance cabinet strength, and increased cabinet rigidity
Optimized fan orifice – optimizes airflow and reduces unit
sound
Rust resistant screws – confirmed through 1500-hour salt
spray testing
PlusOne™ Expanded Valve Space – 3"-4"-5" service valve
space – provides a minimum working area of 27-square
inches for easier access
Integrated heat pump lift receptacle – allows standard CPVC
stands to be inserted into the base
PlusOne™ Triple Service Access – 15" wide, industry lead-
ing corner service access – makes repairs easier and faster.
The two fastener removable corner allows optimal access to
internal unit components. Individual louver panels come out
once fastener is removed, for faster coil cleaning and easier
cabinet reassembly
Diagnostic service window with two-fastener opening –
provides access to the TXV valves and the heat pump revers-
ing valve before opening the unit.
External gauge port access – allows easy connection of
“low-loss” gauge ports
Single-row condenser coil – makes unit lighter and allows thor-
ough coil cleaning to maintain “out of the box” performance
35% fewer cabinet fasteners and fastener-free base – allow
for faster access to internal components and hassle-free
panel removal
Service trays – hold fasteners or caps during service calls
QR code – provides technical information on demand for
faster service calls
Fan motor harness with extra-long wires – allows unit top to
be removed without disconnecting fan wire
Air
Heat Pumps
RP15 Series
“Proper sizing and installation of equipment is critical to achieve
optimal performance. Ask your Dealer for details or visit
www.energystar.gov.”