Specification Sheet

20
Air
Performance Data
RP15 Series
RGPT: Single Stage Upflow Constant Torque 80% Furnace Ratings
Outdoor
Unit
Furnace Indoor Coil
Total Capacity
BTU/H [kW]
Net Sensible
BTU/H [kW]
Net Latent
BTU/H [kW]
SEER EER
Indoor CFM
[L/s]
47 Degree Heating
Capacity BTU/H
[kW]
47 Degree
COP
17 Degree Heating
Capacity BTU/H
[kW]
47 Degree
COP
Region
IV HSPF
AHRI#
RP1548AC1 RGPT-10?BRM?
RCF4821STAM 46000 [13.5] 32400 [9.5] 13600 [4.0] 15 12.5 1400 [660.7] 44500 [13.0] 3.66 28600 [8.4] 2.54 8.5 7512127
RCF4824STAM 46000 [13.5] 32400 [9.5] 13600 [4.0] 15 12.5 1400 [660.7] 44500 [13.0] 3.66 28600 [8.4] 2.54 8.5 7512145
RP1548AJ1 RGPT-07?BRQ?
RCF4821STAM 46000 [13.5] 32400 [9.5] 13600 [4.0] 15 12.5 1400 [660.7] 44500 [13.0] 3.66 28800 [8.4] 2.54 8.5 7512163
RCF4824STAM 46000 [13.5] 32400 [9.5] 13600 [4.0] 15 12.5 1400 [660.7] 44500 [13.0] 3.66 28800 [8.4] 2.54 8.5 7512181
RP1548AJ1 RGPT-10?BRM?
RCF4821STAM 46000 [13.5] 32400 [9.5] 13600 [4.0] 15 12.5 1400 [660.7] 44500 [13.0] 3.66 28600 [8.4] 2.54 8.5 7512164
RCF4824STAM 46000 [13.5] 32400 [9.5] 13600 [4.0] 15 12.5 1400 [660.7] 44500 [13.0] 3.66 28600 [8.4] 2.54 8.5 7512182
RP1560AC1 RGPT-07?BRQ? RCF6024STAM 57000 [16.7] 40600 [11.9] 16400 [4.8] 14 11.5 1700 [802.3] 56500 [16.6] 3.76 35600 [10.4] 2.6 8.5 7512217
RP1560AC1 RGPT-10?BRM? RCF6024STAM 57000 [16.7] 40400 [11.8] 16600 [4.9] 14 11.5 1675 [790.5] 56000 [16.4] 3.7 35600 [10.4] 2.6 8.5 7512218
RP1560AC1 RGPT-12?ARM? RCF6024STAM 56500 [16.6] 39500 [11.6] 17000 [5.0] 14 11.5 1625 [766.9] 56000 [16.4] 3.7 35400 [10.4] 2.54 8.5 7512219
RP1560AJ1 RGPT-07?BRQ? RCF6024STAM 57000 [16.7] 40600 [11.9] 16400 [4.8] 14 11.5 1700 [802.3] 56500 [16.6] 3.76 35600 [10.4] 2.6 8.5 7512250
RP1560AJ1 RGPT-10?BRM? RCF6024STAM 57000 [16.7] 40400 [11.8] 16600 [4.9] 14 11.5 1675 [790.5] 56000 [16.4] 3.7 35600 [10.4] 2.6 8.5 7512251
RP1560AJ1 RGPT-12?ARM? RCF6024STAM 56500 [16.6] 39500 [11.6] 17000 [5.0] 14 11.5 1625 [766.9] 56000 [16.4] 3.7 35400 [10.4] 2.54 8.5 7512252
Performance Data @ AHRI Standard Conditions – Heat Pump (con’t.)