Specification Sheet
22
Air
Performance Data
RP15 Series
RGPE: Two-Stage, Variable Speed 80% (upflow/horizontal) furnace with Comfort Control System Ratings
Outdoor
Unit
Furnace Indoor Coil
Total Capacity
BTU/H [kW]
Net Sensible
BTU/H [kW]
Net Latent
BTU/H [kW]
SEER EER
Indoor CFM
[L/s]
47 Degree Heating
Capacity BTU/H
[kW]
47 Degree
COP
17 Degree Heating
Capacity BTU/H
[kW]
47 Degree
COP
Region
IV HSPF
AHRI#
RP1548AC1 RGPE-10?BRM?
RCF4821STAM 46500 [13.6] 33900 [9.9] 12600 [3.7] 14.5 12 1550 [731.5] 45000 [13.2] 3.6 29200 [8.6] 2.54 8.5 7512125
RCF4824STAM 46500 [13.6] 33900 [9.9] 12600 [3.7] 14.5 12 1550 [731.5] 45000 [13.2] 3.6 29200 [8.6] 2.54 8.5 7512142
RP1548AC1 RGPE-12?ARM? RCF4824STAM 46000 [13.5] 32600 [9.6] 13400 [3.9] 15 12.5 1425 [672.5] 44000 [12.9] 3.66 28600 [8.4] 2.54 8.5 7512143
RP1548AJ1 RGPE-07?BRQ?
RCF4821STAM 46000 [13.5] 32400 [9.5] 13600 [4.0] 14.5 12 1400 [660.7] 44000 [12.9] 3.6 28400 [8.3] 2.5 8.5 7512161
RCF4824STAM 46000 [13.5] 32400 [9.5] 13600 [4.0] 14.5 12 1400 [660.7] 44000 [12.9] 3.6 28400 [8.3] 2.5 8.5 7512178
RP1548AJ1 RGPE-10?BRM?
RCF4821STAM 46500 [13.6] 33900 [9.9] 12600 [3.7] 14.5 12 1550 [731.5] 45000 [13.2] 3.6 29200 [8.6] 2.54 8.5 7512162
RCF4824STAM 46500 [13.6] 33900 [9.9] 12600 [3.7] 14.5 12 1550 [731.5] 45000 [13.2] 3.6 29200 [8.6] 2.54 8.5 7512179
RP1548AJ1 RGPE-12?ARM? RCF4824STAM 46000 [13.5] 32600 [9.6] 13400 [3.9] 15 12.5 1425 [672.5] 44000 [12.9] 3.66 28600 [8.4] 2.54 8.5 7512180
RP1560AC1 RGPE-10?BRM?
RCF6024HTAM 57000 [16.7] 40000 [11.7] 17000 [5.0] 14.5 12 1625 [766.9] 55000 [16.1] 3.7 35000 [10.3] 2.54 8.5 7512202
RCF6024STAM 57000 [16.7] 40000 [11.7] 17000 [5.0] 14.5 12 1625 [766.9] 55000 [16.1] 3.7 35000 [10.3] 2.54 8.5 7512215
RP1560AC1 RGPE-12?ARM?
RCF6024HTAM 57000 [16.7] 40000 [11.7] 17000 [5.0] 14.5 12 1625 [766.9] 55000 [16.1] 3.7 35000 [10.3] 2.6 8.5 7512203
RCF6024STAM 57000 [16.7] 40000 [11.7] 17000 [5.0] 14.5 12 1625 [766.9] 55000 [16.1] 3.7 35000 [10.3] 2.6 8.5 7512216
RP1560AJ1 RGPE-10?BRM?
RCF6024HTAM 57000 [16.7] 40000 [11.7] 17000 [5.0] 14.5 12 1625 [766.9] 55000 [16.1] 3.7 35000 [10.3] 2.54 8.5 7512235
RCF6024STAM 57000 [16.7] 40000 [11.7] 17000 [5.0] 14.5 12 1625 [766.9] 55000 [16.1] 3.7 35000 [10.3] 2.54 8.5 7512248
RP1560AJ1 RGPE-12?ARM?
RCF6024HTAM 57000 [16.7] 40000 [11.7] 17000 [5.0] 14.5 12 1625 [766.9] 55000 [16.1] 3.7 35000 [10.3] 2.6 8.5 7512236
RCF6024STAM 57000 [16.7] 40000 [11.7] 17000 [5.0] 14.5 12 1625 [766.9] 55000 [16.1] 3.7 35000 [10.3] 2.6 8.5 7512249
Performance Data @ AHRI Standard Conditions – Heat Pump (con’t.)
[ ] Designates Metric Conversions