Specification Sheet
Physical Data
Model No.# RP1518A RP1524A RP1530A RP1536A RP1542A RP1548A RP1560A
Nominal Tonnage 1.5 2.0 2.5 3.0 3.5 4.0 5.0
Valve Connections
Liquid Line O.D. – in. 3/8 3/8 3/8 3/8 3/8 3/8 3/8
Suction Line O.D. – in. 3/4 3/4 3/4 3/4 7/8 7/8 7/8
Refrigerant (R410A) furnished oz.¹ 106 94 128 124 145 194 223
Compressor Type Scroll
Outdoor Coil
Net face area – Outer Coil 9.1 11.1 17.3 19.8 19.8 24.2 28.3
Net face area – Inner Coil — — — — — — —
Tube diameter – in. 3/8 3/8 3/8 3/8 3/8 3/8 3/8
Number of rows 1 1 1 1 1 1 1
Fins per inch 20 20 20 20 20 20 20
Outdoor Fan
Diameter – in. 20 20 24 24 24 26 26
Number of blades 2 3 3 3 3 3 3
Motor hp 1/8 1/8 1/5 1/3 1/5 1/3 1/5
CFM 2200 2480 3850 3120 3815 4380 3655
RPM 1075 1075 825 910 825 870 850
watts 156 132 196 135 202 266 274
Shipping weight – lbs. 130 138 167 179 187 215 243
Operating weight – lbs. 123 131 160 172 180 208 236
Electrical Data
Line Voltage Data (Volts-Phase-Hz)
208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60
Maximum overcurrent protection (amps)² 20 25 30 35 40 40 50
Minimum circuit ampacity³ 12 17 19 23 24 26 31
Compressor
Rated load amps 9 12.8 14.1 15.4 17.9 18.5 23.7
Locked rotor amps 48 58.3 73 83.9 112 124 152.5
Condenser Fan Motor
Full load amps 0.7 0.7 1 2.8 1 2.8 1
Locked rotor amps 1.2 1.3 1.5 0 1.5 0 2.3
Line Voltage Data (Volts-Phase-Hz) — — — 208/230-3-60 208/230-3-60 208/230-3-60 208/230-3-60
Maximum overcurrent protection (amps)² — — — 25 30 30 35
Minimum circuit ampacity³ — — — 16 18 21 21
Compressor
Rated load amps — — — 10.4 13.5 13.8 15.9
Locked rotor amps — — — 73 88 83.1 110
Condenser Fan Motor
Full load amps — — — 2.8 1 2.8 1
Locked rotor amps — — — 0 1.5 0 2.3
Line Voltage Data (Volts-Phase-Hz) — — — 480-3-60 480-3-60 480-3-60 480-3-60
Maximum overcurrent protection (amps)² — — — TBD TBD TBD TBD
Minimum circuit ampacity³ — — — TBD TBD TBD TBD
Compressor
Rated load amps — — — TBD TBD TBD TBD
Locked rotor amps — — — TBD TBD TBD TBD
Condenser Fan Motor
Full load amps — — — TBD TBD TBD TBD
Locked rotor amps — — — TBD TBD TBD TBD
¹Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the installation instructions for information about set length and additional
refrigerant charge required.
²HACR type circuit breaker of fuse.
³Refer to National Electrical Code manual to determine wire, fuse and disconnect size requirements.
Air
Physical Data/Electrical Data
RP15 Series
8