Specification Sheet

Physical Data
Model No.# RP1518A RP1524A RP1530A RP1536A RP1542A RP1548A RP1560A
Nominal Tonnage 1.5 2.0 2.5 3.0 3.5 4.0 5.0
Valve Connections
Liquid Line O.D. – in. 3/8 3/8 3/8 3/8 3/8 3/8 3/8
Suction Line O.D. – in. 3/4 3/4 3/4 3/4 7/8 7/8 7/8
Refrigerant (R410A) furnished oz.¹ 106 94 128 124 145 194 223
Compressor Type Scroll
Outdoor Coil
Net face area – Outer Coil 9.1 11.1 17.3 19.8 19.8 24.2 28.3
Net face area – Inner Coil
Tube diameter – in. 3/8 3/8 3/8 3/8 3/8 3/8 3/8
Number of rows 1 1 1 1 1 1 1
Fins per inch 20 20 20 20 20 20 20
Outdoor Fan
Diameter – in. 20 20 24 24 24 26 26
Number of blades 2 3 3 3 3 3 3
Motor hp 1/8 1/8 1/5 1/3 1/5 1/3 1/5
CFM 2200 2480 3850 3120 3815 4380 3655
RPM 1075 1075 825 910 825 870 850
watts 156 132 196 135 202 266 274
Shipping weight – lbs. 130 138 167 179 187 215 243
Operating weight – lbs. 123 131 160 172 180 208 236
Electrical Data
Line Voltage Data (Volts-Phase-Hz)
208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60
Maximum overcurrent protection (amps)² 20 25 30 35 40 40 50
Minimum circuit ampacity³ 12 17 19 23 24 26 31
Compressor
Rated load amps 9 12.8 14.1 15.4 17.9 18.5 23.7
Locked rotor amps 48 58.3 73 83.9 112 124 152.5
Condenser Fan Motor
Full load amps 0.7 0.7 1 2.8 1 2.8 1
Locked rotor amps 1.2 1.3 1.5 0 1.5 0 2.3
Line Voltage Data (Volts-Phase-Hz) 208/230-3-60 208/230-3-60 208/230-3-60 208/230-3-60
Maximum overcurrent protection (amps)² 25 30 30 35
Minimum circuit ampacity³ 16 18 21 21
Compressor
Rated load amps 10.4 13.5 13.8 15.9
Locked rotor amps 73 88 83.1 110
Condenser Fan Motor
Full load amps 2.8 1 2.8 1
Locked rotor amps 0 1.5 0 2.3
Line Voltage Data (Volts-Phase-Hz) 480-3-60 480-3-60 480-3-60 480-3-60
Maximum overcurrent protection (amps)² TBD TBD TBD TBD
Minimum circuit ampacity³ TBD TBD TBD TBD
Compressor
Rated load amps TBD TBD TBD TBD
Locked rotor amps TBD TBD TBD TBD
Condenser Fan Motor
Full load amps TBD TBD TBD TBD
Locked rotor amps TBD TBD TBD TBD
¹Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the installation instructions for information about set length and additional
refrigerant charge required.
²HACR type circuit breaker of fuse.
³Refer to National Electrical Code manual to determine wire, fuse and disconnect size requirements.
Air
Physical Data/Electrical Data
RP15 Series
8