FORM NO. A66-220 REV. 4 AIR CONDITIONERS Features ■ ■ ■ ■ ■ ■ Outdoor air conditioner designed for ground level or rooftop installations. These units offer comfort and dependability for single, multi-family and light commercial applications. Painted louvered steel cabinet Easily accessible control box Condenser coils constructed with copper tubing and enhanced aluminum fins Grille/Motor mount for quiet fan operation Filter Drier (shipped – not installed) WA14 SERIES 14 SEER/11.5 EER Nominal Sizes 1.
Table of Contents WA14 Series TABLE OF CONTENTS Model Number Identification ........................................................................3-4 Electrical & Physical Data ................................................................................5 Unit Dimensions ............................................................................................6 Refrigerant Line Size Information ..................................................................7-8 Performance Data ...................
A 13 24 Product Category P - Heat Pump Brand Product Category C - Evap Coil Brand F - Furn Coil H - Air-Handler Coil Type F [ ] Designates Metric Conversions Generic C T 24 A Width 17 S S- Standard Eff. M- Mid Eff. H- High Eff. A Controls N Controls N M M - Multipoise V - Vertical only/ convertible H - Ded.
WeatherKing P - PSC T - Constant Torque 92 - 92 AFUE 95 - 95 AFUE 96 - 96 AFUE WeatherKing A - 1st Design B - 2nd Design C - 3rd Design Major Rev A 1 - Single-stage 80 - 80+ AFUE WeatherKing H 1 [ ] Designates Metric Conversions Motor V T 70 Capacity BTU/HR 24 - 24,000 [7.03 kW] 36 - 36,000 [10.55 kW] 48 - 48,000 [14.07 kW] 60 - 60,000 [17.
Electrical and Physical Data WA14 Series Electrical and Physical Data Physical Data Model No. Nominal Tonnage Valve Connections Liquid Line O.D. – in. Suction Line O.D. – in. Refrigerant (R410A) furnished oz.¹ Compressor Type Outdoor Coil Net face area – Outer Coil Net face area – Inner Coil Tube diameter – in. Number of rows Fins per inch Outdoor Fan Diameter – in. Number of blades Motor hp CFM RPM watts Shipping weight – lbs. Operating weight – lbs.
Unit Dimensions WA14 Series Unit Dimensions MODEL NUMBER OPERATING H (Height) L (Length) H (Height) L (Length) W (Width) INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm WA1418A 24.25 615 23.63 600 23.63 600 24.25 615 24.75 628 24.75 628 WA1424C 24.25 615 27.63 701 27.63 701 24.25 615 28.75 730 28.75 730 WA1430B 24.25 615 27.63 701 27.63 701 24.25 615 28.75 730 28.75 730 WA1436B 32.25 819 27.63 701 27.63 701 32.50 825 28.
Allowable Suction Line Size 5/8" 5/8" 5/8" **3/4"** * *3/4"** **3/4"** 5/8" 5/8" 5/8" 3/4" 3/4" 3/4" 5/8" 5/8" 3/4" 3/4" 5/8" 5/8" 3/4" 3/4" 3/4" 7/8" 7/8" 7/8" 3/4" 3/4" 7/8" 7/8" 3/4" 3/4" 7/8" 7/8" 3/4" 3/4" 7/8" 7/8" 1-1/8" 1-1/8" Allowable Liquid Line Size 1/4" 5/16" 3/8" 1/4" 5/16" 3/8" 1/4" 5/16" 3/8" 1/4" 5/16" 3/8" 5/16" 3/8" 5/16" 3/8" 5/16" 3/8" 5/16" 3/8" 1/2" 5/16" 3/8" 1/2" 3/8" 1/2" 3/8" 1/2" 3/8" 1/2" 3/8" 1/2" 3/8" 1/2" 3/8" 1/2" 3/8" 1/2" WA13 N/R 225 150 N/R 225 150 N/R 223 148 N/R 22
Allowable Liquid Line Size mm [in.] WeatherKing 15.88 [5/8] 15.88 [5/8] 15.88 [5/8] 19.05 [3/4]** 19.05 [3/4]** 19.05 [3/4]** 15.88 [5/8] 15.88 [5/8] 15.88 [5/8] 19.05 [3/4] 19.05 [3/4] 19.05 [3/4] 15.88 [5/8] 15.88 [5/8] 19.05 [3/4] 19.05 [3/4] 15.88 [5/8] 15.88 [5/8] 19.05 [3/4] 19.05 [3/4] 19.05 [3/4] 22.23 [7/8] 22.23 [7/8] 22.23 [7/8] 19.05 [3/4] 19.05 [3/4] 22.23 [7/8] 22.23 [7/8] 19.05 [3/4] 19.05 [3/4] 22.23 [7/8] 22.23 [7/8] 19.05 [3/4] 19.05 [3/4] 22.23 [7/8] 22.23 [7/8] 28.58 [1-1/8] 28.
Performance Data WA14 Series Performance Data @ AHRI Standard Conditions—Cooling Note: Ratings contained in this document are subject to change. For up-to-date and expanded ratings, please visit the AHRI web site (www.ahridirectory.org). High Sales Volume Tested Combination (HSVTC) Outdoor Unit Indoor Coil or Air Handler Total Capacity BTU/H [kW] Net Sensible BTU/H [kW] Net Latent BTU/H [kW] SEER EER Indoor CFM [L/s] 600 [283.2] WA1418AJ1 TCF2417STA+RXMD-C04 17100 [5.0] 13300 [3.9] 4700 [1.
Performance Data WA14 Series Performance Data @ AHRI Standard Conditions—Cooling (con’t.) Note: Ratings contained in this document are subject to change. For up-to-date and expanded ratings, please visit the AHRI web site (www.ahridirectory.org). W801T: Single-Stage X-13 80% Furnace Ratings Outdoor Unit WA1418AJ1 WA1424C Furnace Net Latent BTU/H [kW] SEER EER Indoor CFM [L/s] TCF2417STA 17100 [5.0] 13300 [3.9] 4700 [1.4] 16.00 13.00 625 [295.0] TCF2417STA 17100 [5.0] 13300 [3.9] 4700 [1.
Performance Data WA14 Series Performance Data @ AHRI Standard Conditions—Cooling (con’t.) Note: Ratings contained in this document are subject to change. For up-to-date and expanded ratings, please visit the AHRI web site (www.ahridirectory.org). W801T: Single-Stage X-13 80% Furnace Ratings Outdoor Unit Furnace 24200 [7.1] 34200 [10.0] 21000 [6.2] TCF3624HTA 34200 [10.0] TCF3624MTA TCF3624HTA 15.10 12.50 11200 [3.3] 14.00 11.50 950 [448.4] 23600 [6.9] 11800 [3.5] 16.00 13.00 1025 [483.
Performance Data WA14 Series Performance Data @ AHRI Standard Conditions—Cooling (con’t.) Note: Ratings contained in this document are subject to change. For up-to-date and expanded ratings, please visit the AHRI web site (www.ahridirectory.org). W95T: 95% AFUE single-stage Constant Torque Multipoise Gas Furnace Ratings Outdoor Unit WA1418AJ1 WA1424C Furnace Indoor CFM [L/s] 13300 [3.9] 4700 [1.4] 15.10 12.50 625 [295.0] 17100 [5.0] 13300 [3.9] 4700 [1.4] 15.10 12.50 600 [283.
Performance Data WA14 Series Performance Data @ AHRI Standard Conditions—Cooling (con’t.) Note: Ratings contained in this document are subject to change. For up-to-date and expanded ratings, please visit the AHRI web site (www.ahridirectory.org). W96TA Ratings Outdoor Unit WA1418AJ1 WA1424C Furnace Net Sensible BTU/H [kW] Net Latent BTU/H [kW] SEER EER Indoor CFM [L/s] TCF2417STA 17100 [5.0] 13300 [3.9] 4700 [1.4] 15.10 12.50 625 [295.0] W96TA0402317M TCF2417MTA 22800 [6.7] 16200 [4.
Performance Data WA14 Series Performance Data @ AHRI Standard Conditions—Cooling (con’t.) Note: Ratings contained in this document are subject to change. For up-to-date and expanded ratings, please visit the AHRI web site (www.ahridirectory.org). W96TA Ratings Outdoor Unit WA1442C Furnace SEER EER Indoor CFM [L/s] 40000 [11.7] 29700 [8.7] 10300 [3.0] 14.00 11.50 1200 [566.3] TCF4821MTA 39500 [11.6] 28500 [8.4] 11000 [3.2] 14.00 11.50 1100 [519.1] W96TA0702317M TCF4821MTA 40000 [11.
Performance Data WA14 Series Performance Data @ AHRI Standard Conditions—Cooling (con’t.) Note: Ratings contained in this document are subject to change. For up-to-date and expanded ratings, please visit the AHRI web site (www.ahridirectory.org). Air Handler Ratings Outdoor Unit WA1418AJ1 WA1424C WA1430BJ1 WA1436BJ1 WA1442C WA1448BJ1 WA1460AJ1 [ Total Capacity BTU/H [kW] Net Sensible BTU/H [kW] Net Latent BTU/H [kW] SEER EER Indoor CFM [L/s] WBHP-17 17100 [5.0] 13300 [3.9] 4700 [1.
Limited Warranty WA14 Series GENERAL TERMS OF LIMITED WARRANTY* WeatherKing will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty. *For complete details of the Limited and Conditional Warranties, including applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certificate. 16 WeatherKing Parts.....................
Notes WA14 Series WeatherKing 17
Features WA14 Series 18 WeatherKing
Mechanical Specifications WA14 Series WeatherKing 19
Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices. ® “In keeping with its policy of continuous progress and product improvement, WeatherKing reserves the right to make changes without notice.” PRINTED IN U.S.A. 1-19 QG FORM NO. A66-220 REV. 4 S u p ers ed es Form N o . G 66- 536 R e v.