Use and Care Manual

17
24-Hour Leak Detection Override
Mute Alarm Beep
CLEAR
ALARM
VACATION 110
UNLOCK/LOCK
120
(3 SEC)
130 140 150
WiFi
SETUP
SERVICE NEEDED
SET POINT (°F)
CLEAR
ALARM
VACATION 110
UNLOCK/LOCK
120
(3 SEC)
130 140 150
WiFi
SETUP
SERVICE NEEDED
SET POINT (°F)
Press the CLEAR ALARM button for 1 second. The
controller will beep after the button is released. This
will silence the alarm beep and allow the heater to
run normally for 24-hours.
If water is detected while the override is active, the
SERVICE NEED indicator will be solid and the
EcoNet app will display an alert.
Prior to using the 24 hour override feature, check to determine the source of the leak. If
the leak is not coming from the water heater, stop the leak if possible and clean any excess
water around the water heater. Contact the Rheem call center or your local plumber if leak
detection alert persists after the 24 hour override. The use of a fan can shorten the time
to dry any residual moisture around the water heater. If a leak is coming from the water
heater, call for service.
Press the CLEAR ALARM button. This will silence
the alarm beep.
The alarm condition will remain and must be
corrected in order to remove the LED and silence the
beep permanently.
NOTE: The nature
of a water heater
install often result in
spilled water which
can trigger the leak
detection alarm and
closing of shutoff
valve, disabling the
water heater.
WARNING: The
use of heat to dry
the residual moisture
from a spill or leak is
NOT PERMITTED.