Use and Care Manual

17
Local Startup
Current Mode
Scald Warning
Current Set Point
Fault Indicator
Current Alarm
& History
Scroll Available
Enable/Disable
Clear Alarm
WiFi Setup &
Indicator
Enter / Select
Text Display
Next Screen /
Option
Mode Toggle
Temp & Value
Adjustment
User Interface
ICONS show the current state of the entire system.
1. Current Mode - Illuminated when the system is working on the corresponding mode.
2. Wi-Fi Indicator - Illuminated when the display detects valid connection to a Wi-Fi network. Blink-
ing when in provisioning mode.
3. Fault Indicator - Illuminated when the display detects OBJECT codes ALMCODE 1, 2, 3 or 4 is
greater than "0". This indicates the Control Board has detected either an Alarm or an Alert.
4. Scroll Available Indicator - Illuminated when the display detects the Up/Down arrows are enabled
to scroll.
5. Scald Warning - Illuminated when the display detects potential scalding water temperatures. Use
water at own risk.
6. Enable/Disable Indicator - Illuminated when the display is Enabled (ON).
Operating Mode
Press the "Mode" button to utilize the five major
modes of operation: The active mode is displayed on
the top of the screen.
Heat Pump Only
This mode will heat with compressor operation
only and will not use any electric heat during
typical heating and demand cycles, This mode will
Minimize power consumption.
Energy Saver - Factory set mode for
shipping.
This mode optimizes compressor and electric heat
that results in water heater performance that meets
Energy Star requirements.
As result, compressor operation will be maximized
and use of electric heat will be minimized.
High Demand
This mode will maximize the performance of the
water heater while still providing good energy
savings. Water heater operates with simultaneous
compressor and electric heat.
Electric Only
This Mode will heat with the electric resistance
elements. This mode should only be used during
compressor maintenance periods. This mode will
result in maximum power consumption.
Vacation
This mode will allow during setting between 2 and
28 days or set indefinitely with the "Hold" setting.
Tank temperature will be maintained at about 82°F.
Only compressor operation will be allowed as
needed.