User Manual

Under-Counter Beverage Cooler
Edition: A (March 2012) - 9 -
and hold the DOWN / LIGHT keypad button for at least 0.5 seconds. The light
will be either powered on or off accordingly.
If the compressor light is flashing on the electronic display
The compressor is designed to have a minimum resting period of 6 minutes. If
the electronics command the compressor to start, but it is in resting mode, then
the compressor light will flash. This is normal and nothing to be concerned
about.
Adjusting the temperature of Standard Mode
The appliance is set up to run without interference from the user. It is not
recommended for the user to interfere with the complex electronic set up.
However if the user wishes to change the temperature of the Standard Mode
then it can be done by altering the ST parameter. ST is the lowest temperature
that the user wishes the appliance to run at. The appliance will run at ST plus 2
degrees. For example if you wish to have an average temperature of 6
degrees inside the cabinet then you would select ST at a value of 4:
1. Press the SET keypad button for at least 3 seconds until “ 0 “ is
displayed.
2. Press the UP / ES keypad button 22 times until “ 22 “ is displayed .
3. Press the SET keypad button and the display will change to “PS”
4. Press the UP / ES keypad button 7 times until “ ST “ is displayed.
5. “ 0 “ will appear on the display
6. Using the “Down/Light” or “Up / ES” button, select the ST minimum
temperature value you prefer.
7. Press the “SET” keypad button once again will lock in the parameter
change.