Instruction manual

LOCATION GUIDE FOR SYSTEM COMPONENTS
THE SIREN: Mount the siren to the vehicle’s firewall, close to the bonnet.
DO NOT
mount near the exhaust manifold or low down in the engine bay where it may be
exposed to excessive moisture / road grime etc.
THE CONTROL (MAIN) UNIT: Mount under the dash between the steering column &
t
he centre of the vehicle. Cable tie the unit to a large cable (20mm diameter or larger)
or to a heavy strut.
SECURITY OVERRIDE MODE:
If a customer loses a remote control, or it fails to disarm the alarm system, the
following procedure will disarm the alarm system.
1. Open & close the drivers door - sit in the vehicle. (The siren will sound).
2. Within 30 seconds, turn the ignition from off to on 10 times (initial factory securit
y
override setting - can be changed from 5 - 25 times - see Programmable Features
Section contained earlier in this manual). Wait for 30 seconds.
3. The system will then disarm ( the siren will stop sounding), but the blinkers will flash
for 3 minutes.
4. Contact your Rhino Dealer for further assistance.
IMPORTANT NOTE FOR INSTALLERS
:
Vehicles fitted with negative
or positive switching doors.
In order for the alarm system to function correctly, it is necessary for the doors to be
hard wired to the system. Please follow the wiring diagrams below:
NEGATIVE SW ITCHING DOORS: POSITIVE SW ITCHING DOORS:
Use relay.
+12V
Interior light
Pink wire ALARM 86
30 87a 87 Pink wire ALARM
Door Switch
85
Door Switch
+12V
9