Installation manual

10 Benchmark Series Low-Profile Bench Scale
4.3.1 Load Cell Wiring to Summing Board
The four load cells are each wired to their respective terminals in the summing board according to the corner
numbering system shown in Figure 4-3 and the coloring code in Table 4-1.
Hole for homerun cable
Figure 4-3. Corner numbering (top view)
Table 4-1. Load Cell Wiring
Cable Color Code Summing Board Terminal
Green + Excitation
Black - Excitation
White + Signal
Red - Signal
4.4 Replacement Load Cells
Table 4-2. Replacement load cells
Capacity of
Scale
Load Mount Load Cell
100 lbs 96823 100272
250 lbs 96824 104645
500 lbs 96825 100273
1000 lbs 96826 100274