Service manual

Installation 11
2.5 Gate and Latch Adjustment Procedure
Assemble gates according to the following criteria:
Hinge Bolts - Assemble with lock washer on inside of gate and jam nut on the outside.
Hinge Side Gap - Approximately 3” between the gate and the corner post.
Gate Latch Pin - Install rubber tubing on the latch pin (Mobile units only).
Adjust gates as follows:
1. Adjust the hinge bolts to align the top of the gate on the latch side with the top of the cage wall.
2. Adjust the hinge bolts so the latch side gap is about 1 1/2”.
3. Install and adjust the latch so the gate latch pin does not rub on the top or bottom of the latch. Adjust the
hinge bolts only if necessary.
4. Ratchet straps can be used diagonally to help square up gates to walls.
2.6 T-Belt
Ensure the T-Belt hold down loops are installed and hooked into the corner posts of the cage.
Figure 2-5. T-Belt
2.7 Optional 920i Weighcenter Mounting
The MAS-P is NTEP approved only when purchased with 920i Weighcenter. When using other indicators, it
must be re-calibrated each time it’s moved.
1. Before installing the bracket, a bead of silicone must be
added. See Figure 2-6.
2. Clean the wall tubes where the bracket will mount and the
space between the holes on the mount bracket with
mineral spirits.
3. Place the mounting bracket onto the cage wall by pressing
the adhesive tightly to the cage.
4. Secure with four bolts.
5. Mount the weighcenter onto the mounting bracket and
route the cable as shown in Figure 2-6.
6. Install the clamps to secure the conduit.
• Mount the upper conduit clamp using the lower left
mounting bracket bolt.
Secure the lower end of the conduit by drilling a hole
through the cage sheeting and installing the clamp with
the bolt provided.
Note
Hold Down
Loop
Note
Silicone
Conduit Clamp 9/32Ø
Silicone Detail
Figure 2-6. Weighcenter Mounting