14 Multiple Animal Scale Portable - Installation Manual
2.9 Load Cell Wiring Diagrams
Load cell wiring shown is effective for all models built after 09/17/2013. Models built prior to this date should
rewire the scale to the updated configuration. For information on rewire download Technical Bulletin PN 159193
from www.ricelake.com.
Figure 2-9. Load Cell Wiring Diagram
Note
Trimmers
Load Cell #4
Load Cell #1
Load Cell #2
Load Cell #3
Indicator
Black
Green
White
Shield
Red
+E
-E
+S
-S
GND
V1 V2 V3 V4
J-Box
Load
Cell 4
Load
Cell 3
Load
Cell 1
Load
Cell 2
Load
Cell 2
Cables
Load
Cell 2 & 3
Cables
Load
Cell 1 & 4
Cable
JP4
PT4 PT3
JP3
JP2
PT1
1
EXP
PT2
JP1
1
CELL4
1
CELL1
1
CELL3
1
CELL2
1
IND
-EX
-SI
SHD
+SI
+EX
M
-SI
S2C
+SI
+EX
-EX
-SI
SHD
+SI
+EX
-EX
-SI
SHD
+SI
+EX
+SI
-SI
-EX
SHD
-EX
SHD
+EX
+SE
-SE
Load
Cell 4
Load
Cell 3
Load
Cell 1
Load
Cell 2
Add 20 ft of cable to load cell 1 for
18 ft mobile scale.
Add 10 ft of cable to load cell 1 for
13 ft mobile scale.
Note