Service manual

Introduction 5
1.3 Unloading
Follow instructions below to unload the scale.
1.3.1 Slinging the scale.
MAS-P can be slung with four equal length straps connected from the lifting lugs to a single point in the center.
Strap length 8 x 13 = 7 ft minimum
Strap length 8 x 18 = 10 ft minimum
Figure 1-4. Slinging the Scale
1.3.2 Lift the Scale
1. If stacked, monitor the four corners directly below the lifting fixtures. Each corner has a shipping stub
inserted, these stubs are not bolted in place, ensure they remain with the lower scale.
2. Once the upper scale of the stack is removed the stubs can be discarded.
Figure 1-5. Shipping Stub
3. The scale can now be stored as is or placed on a relatively flat location to be assembled.
1.3.3 Remove Lifting Fixture
Remove the lifting fixture after scale has been placed in position.
1. Remove the nylon locknut from the bolt installed for shipping.
2. Remove the lifting fixture from the bolt.
3. Reinstall the nut, retain the lifting fixture for future moves.
9 FEET
11 FEET
Shipping Stub
Lifting
Fixture
Nylon
Locknut
Figure 1-6. Lifting Fixture