Manual

6 Versa-portion RLP-S/SM Operation Manual
3.5 Internal Count and A/D Count Display
1.With the unit in weigh mode, press and hold the ZERO key.
2.With the
ZERO key held, press and release the TARE key twice, then press and
release the POWER key.
The display will show ,,,,,0,.
3.Press the
POWER key to display the A/D count.
4.To return to weigh mode, press the
TARE key.
Note
(G) uppercase is the abbreviation for gross.
(g) lowercase is the correct abbreviation for grams.
06 Auto tare clear when
re
zero
0 - Allow
1 - Prohibit
Weight reset when tare
0 - Allow
1 - Prohibit
Tare auto clear
(Greater or equal to
Gross 21e and greater or
equal toNet 5e)
0 - Allow
1 - Prohibit
07 Zero tracking when Tare
0 - Allow
1 - Prohibit
Re-zero function
0 - Allow
1 - Prohibit
Additional zero for weight
when only
fixed zeros are
displayed (V1.02 and
above)
0 - Allow (NTEP)
1 - Prohibit
08 Unit key (Not used on Versa-portion RLP-SM)
000 - No
001 - For g and lb conversion
010 - Not used
011 - G, lb and oz
100 - 111 Not used
SPEC
Number
Bit 2 Bit 1 Bit 0
Table 3-1. SPEC Number And Bit Explanation (Defaults Are Bold) (Continued)