Technical Specifications
Essential
Essential Direct Vent gas water heaters use outside air for combustion,
offer longer venting options and a coaxial vent for easy installation
RichmondWaterHeaters.com
RICHMOND
®
WATER HEATERS
In keeping with its policy of continuous progress and product improvement, Richmond reserves the right to make changes without notice.
Richmond Water Heaters • 1115 Northmeadow Parkway, Suite 100, Roswell, Georgia 30076
© Rheem Manufacturing Company •
01/18
•
FORM NO. T-637 Rev. 4
Essential
Direct Vent
40 and 50-Gallon Capacities
Up to 36,000 BTU/h
Natural and LP Gas
EFFICIENCY
• .56 - .58 UEF
• Well insulated for reduced stand-by
heat loss
PERFORMANCE
• FHR: 51 gallons
• Recovery: 30.3 to 36.4 GPH at a 90° F
rise, depending on model
TECHNOLOGY
• Adjustable coaxial vent allows exibility
of installation, can swivel 360 degrees
and uses outside air for combustion and
requires no electrical power
• Aluminum vent and cap base to prevent
staining of building exterior
LONGER VENTING
• Up to 4 feet above the water heater and
4 feet from an outside wall
• Order Horizontal Vent Kit: #SP20131
• Order Vertical Vent Kit: #SP20132
ALTITUDE CERTIFICATION
• All models certied up to 5,999 ft. above
sea level
LOW EMISSIONS
• Meets 40 ng/J NOx requirements
LONGER LIFE
• Premium grade anode rod provides
long-lasting tank protection
PLUS…
• Temperature and pressure relief valve
included
• Low lead compliant
• Specially formulated glass lining
prevents corrosion and extends the life
of the tank
• Heat saving ue bafe design
• Gas control and combination thermostat
• Piezo ignition
• High temperature silicone bands reduce
venting installation time
• Internal air tube for reduced footprint
• EverKleen
™
patented system ghts
sediment build-up
WARRANTY
• 6-Year limited tank and parts warranty*
* See Residential Warranty Certicate for complete
information
Units meet or exceed ANSI requirements and have
been tested according to D.O.E. procedures. Units
meet or exceed the energy efciency requirements of
NAECA, ASHRAE standard 90, ICC Code and all state
energy efciency performance criteria.
Uniform Energy Factor and rated gallon capacity based on Department of Energy (DOE) requirements.
** Horizontal Vent Kit #SP20131 for applications up to 2,000 ft. above sea level. Optional horizontal venting not applicable for
installations above 2,000 ft. Venting dimensions are approximate.
†
Vertical Vent Kit #SP20132. Venting dimensions are approximate.
G
E
A
B
C
F
D
10"
3/4" N.P.T.
RELIEF VALV E
OPENING
1/2"
EXTERIOR
WALL
(G:
SIDE VENTING
RANGE OF
ADJUSTMENT)
HOT WATER
CONNECTION
COLD WATER
CONNECTION
DESCRIPTION FEATURES ROUGHING IN DIMENSIONS (SHOWN IN INCHES) ENERGY INFO.
T
Y
P
E
NOMINAL
GALLON
CAPACITY
RATED
GALLON
CAPACITY
MODEL
NUMBER
GAS INPUT
IN THOUS.
BTU/H
RECOVERY
IN G.P.H.
90° F RISE
FIRST HOUR
DELIVERY
G.P.H.
H T. T O
VENT
A
TANK
HEIGHT
B
DIAM.
C
H T. T O
GAS
CONN.
D
VENT
SIZE
E
H T. T O
SIDE T&P
VALVE
F
SHIP
WEIGHT
(LBS)
UNIFORM
ENERGY
FACTOR
(UEF)
ESTIMATED
YEARLY
ENERGY
COSTN AT. LP N AT. LP N AT. LP
Tall 40 38 6GDV40F3 36 – 36.4 – 51 – 68-1/4 60-7/8 19-3/4 14-1/4 6 51-5/8 155 0.58 $216
Tall 40 38 6GDV40PF3 – 30 – 30.3 – 51 68-1/4 60-7/8 19-3/4 14-1/4 6 51-5/8 155 0.58 $522
Tall 50 48 6GDV50F3 36 – 36.4 – 51 – 68 59-5/8 21-3/4 14-1/4 6 52-1/2 165 0.56 $237
Tall 50 48 6GDV50PF3 – 33 – 30.3 – 51 68 59-5/8 21-3/4 14-1/4 6 52-1/2 165 0.56 $573
VENTING – ROUGHING IN DIMENSIONS (INCHES)
SIDE VENTING (G) WITH
INCLUDED VENT KIT
SIDE VENTING (G) WITH
OPTIONAL VENT KIT
OPTIONAL HEIGHT
(A) WITH VENT KIT
TYPE MODEL NUMBER 4 FEET VENTING AVAILABLE MIN. MAX. MIN. MAX.
Tall 6DV40F3 Horiz. & Vertical 9-1/8 19-1/8 9-1/8 48** 68-1/4 – 107-3/4
†
Tall 6DV50F3 Horiz. & Vertical 8-1/8 18-1/8 8-1/8 48** 68 – 107
†