Operating instructions

Facsimile Features
130
4
Parameter Settings
This section describes Parameter Settings.
User Parameters allow you to customize various settings to suit your needs. To
change function settings, set the User Parameter Switches.
Switches and Bits
Each User Parameter has a set of switches, and each of the switches consist of
eight bits, whose values are “0" or “1". The right most bit is bit 0 and the left
most is bit 7. You can adjust the settings to match your needs by switching the
value of bits between “0" and “1".
Switch 02:
User Parameter List
User Parameter Switches are outlined in the following table.
00111011
↓↓↓↓↓↓↓↓
76543210
Switch Bit Item 0 1
02 0 Forwarding Mark Off On
02 3 TSI Print Off On
03 0 Automatic printing of the Communication
Result Report
Off On
03 2 Automatic printing of the Memory Storage
Report
Off On
03 3 Automatic printing of the Polling RX Reserve
Report
Off On
03 4 Automatic printing of the Polling RX Result
Report
Off On
03 5 Automatic printing of the Immediate TX Re-
sult Report
Off On
03 6 Automatic printing of the Polling TX Clear
Report
Off On
03 7 Automatic printing of the Journal Off On
04 0 Automatic printing of the Confidential File
Report
Off On
04 1 Automatic printing of Communication Fail-
ure Report and Transfer Result Report
Off On
04 4 Indicates the parties Off On
04 5 Include sender's name on reports Off On
04 7 Include a portion of the image on reports Off On