Service manual

6.4 ID SENSOR CLEANING AND REPLACEMENT
1. Remove the drum from the drum unit (see Drum Replacement)
and keep the drum wrapped in the protective sheet or a clean
sheet of paper.
[Cleaning]
2. Clean the ID sensor [A] with a blower brush from the drum side.
[Replacement]
2. Remove the ID/V sensor bracket [B] from the drum unit (2
screws).
3. Remove the ID sensor board [C] from the drum unit by simply
lifting it up.
4. Reassemble the drum unit and install all the removed units in the
copier.
NOTE: When reinstalling the ID/V sensor bracket, make sure that
the spurs [D] are correctly positioned as shown.
5. Perform the ID/V sensor adjustment (see ID Sensor and V
Sensor Adjustment SP54).
[B]
[C]
[D]
[A]
FT5733/5433 5-54 FSM