6.5 V SENSOR CLEANING AND REPLACEMENT
1. Remove the drum from the drum unit (see Drum Replacement)
and keep the drum wrapped in the protective sheet or a clean
sheet of paper.
[Cleaning]
2. Clean the V sensor [A] with a blower brush from the drum side.
[Replacement]
2. Remove the ID/V sensor bracket [B] from the drum unit (2
screws).
3. Remove the drum stay [C] (2 long screws) from the drum unit.
4. Remove the front drum cover [D] from the unit.
5. Remove the V sensor board [E] from the drum unit (1 connector).
6. Couple the V sensor connector with a new V sensor board and
install the board on the drum unit.
[C]
[D]
[G]
[F]
[E]
[A]
[H]
[B]