Service manual

6.11QUENCHING LAMP REPLACEMENT
1. Remove the copier rear cover.
2. Remove the tension spring [A] of the drum drive belt [B].
3. Slip off the drum drive belt from the tension pulley [C] and lower
the tension pulley.
4. Remove the tension pulley [D] (1 E-ring) for the development
drive belt [E].
5. Slide out the quenching lamp [F] from the copier (1 screw and 1
connector).
6. Install a new quenching lamp and reassemble the copier.
[D]
[E]
[F]
[B]
[C]
[A]
FT5733/5433 5-62 FSM