Service manual

5. If the paper has not stopped against the left scale [A], remove the
left scale (2 shoulder screws).
6. Set a sheet of A4 / 8
1/2" x 11" paper [B] sideways on the
exposure glass edge as shown.
NOTE: This sheet of paper prevents the original from jamming at
the edge of the exposure glass when it is fed in without
the left scale.
7. Set a sheet of A3 / 11" x 17" paper on the DF then press SW101.
8. Just after the paper is fed in, gently pull off the sheet set in step
6.
9. When the paper (set in step 7) stops on the exposure glass after
the inversion, open the DF slowly so that the paper does not
move from the stop position.
[A]
[B]
FT5733/5433 8-34 FSM