Maintenance
Group (Tab) Item Selections Remarks
Print Test
Sheet button
Sends a PCL or GDI command to the
printer to print a test sheet.
It is disabled when tray 2 is not installed.
Adjustment
Horizontal
(-15 to +15)
step
0.34 mm per step. Range is -5 mm to +5
mm.
If the machine settings are reset to the
factory defaults, this value does not
change.
Registration
Tray 2
Adjustment
Vertical
(-15 to +15)
step
0.24 mm per step. Range is -3.6 mm to
+3.6 mm
If the machine settings are reset to the
factory defaults, this value does not
change.
Print Test
Sheet button
Sends a PCL or GDI command to printer
to print a test sheet.
Registration
Bypass
Adjustment
Vertical
(-15 to +15)
step
0.24 mm per step. Range is -3.6 mm to
+3.6 mm