Service manual
Service Menu (MF Model)
G165/G166/G167/G181/G183/G184 5-42 SM
Flatbed Main
Reg.
Adjusts the Flatbed Scan main-scan registration.
(G181 doesn't support this.)
[-2.0 to 2.0 / 0 (Default)/ 0.1 mm/step]
Flatbed Sub
Reg.
Adjusts the Flatbed Scan sub-scan registration.
(G181 doesn't support this.)
[-2.0 to 2.0 / 0 (Default)/ 0.1 mm/step]
ADF Main Reg.
Adjusts the ADF Scan main-scan magnification.
(G181 doesn't support this.)
[-0.9 to 0.9 / 0 (Default)/ 0.1 %/step]
ADF Sub Reg.
Adjusts the ADF Scan sub-scan magnification.
(G181 doesn't support this.)
[-0.9 to 0.9 / 0 (Default)/ 0.1 %/step]
Flatbed Main
Reg.
Adjusts the Flatbed Scan main-scan magnification.
(G181 doesn't support this.)
[-0.9 to 0.9 / 0 (Default)/ 0.1 %/step]
Size Adjust
Flatbed Sub
Reg.
Adjusts the Flatbed Scan sub-scan magnification.
(G181 doesn't support this.)
[-0.9 to 0.9 / 0 (Default)/ 0.1 %/step]
Fax Maintenance (G181 doesn't support this.)
RX Level
Sets the reception level.
[-43 dBm (Default)/ -33 dBm/ -26 dBm
/ -16 dBm]
Modem Settings
TX Level
Sets the transmission level.
[0 dBm/ -1 dBm/ -2 dBm/ -3 dBm/ -4 dBm
/ -5 dBm/ -6 dBm/ -7 dBm/ -8 dBm/ -9 dBm
/ -10 dBm/ -11 dBm/ -12 dBm/ -13 dBm
/ -14 dBm/ -15 dBm]