Service manual
Service Menu (MF Model)
G165/G166/G167/G181/G183/G184 5-44 SM
CNG Cycles
Number of CNG cycles to be detected
This setting is only effective for FAX/TAD mode.
[1.5 Cycle (Default)/ 2.0 Cycle]
Tone Sound
Monitoring
Determines the period when tones from the line
are monitored.
[No Monitoring/ Up To Phase B (Default)/ All TX
Phases]
Stop/Clear key
Pressing the Stop/Clear key can stop the current
receiving operation. Received data is lost.
[Not Functional (Default)/ Functional]
Off-Hook Level
Sets the off-hook detection threshold.
[10V (Default)/ 15V/ 20V/ 25V]
Redial Interval
Sets the redial interval when Tx fails.
[5 Min/ 6 Min]
TX Settings
Redialings
Sets the number of redials when Tx fails.
[2 times/ 3 Times/ 4 Times/ 5 Times]
Overseas
Comm Mode
This sets the machine to ignore a DIS signal sent
from the called station once in a sending
operation.
[Off (Default)/ Ignore DIS Once]
Overseas Comm
Mode Settings
Minimum Time
Length
If this setting is set to "On", the machine detects
the CNG signal after the line is connected. If it is
set to "Off", the machine detects the CNG signal
as long as the line is connected.
[100 Ms/ 200 Ms/ 300 Ms/ 400 Ms (Default)]