Service manual

Fusing and Exit
SM 6-43 G165/G166/G167/G181/G183/G184
Detailed
Descriptions
Section
Target Temperature for Each Paper Type
Paper Type Target Temperature
Thin 175°C
Plain 1 180°C
Recycled 180°C
Plain and Recycled 180°C
Plain 2 175°C
Thick 1 175°C
Cardstock 175°C
Bond 175°C
Envelopes 170°C
Fusing unit related SC codes
If one of the fusing unit components (such as thermistors, thermostat, fusing lamp etc.) is
defective, the following SC codes may be issued. For details, refer to the SC code list in the
chapter "Troubleshooting.”
SC541, 542, 543, 544, and 545
If one of these SC codes is issued, click or press "Fuser SC Reset" with SOM (printer
model) or "Engine Maintenance" (MF model).
Anti-Humidity Mode
To reduce paper curl in high temperature and humidity environments, the fusing unit does
idle rotation before a job, if the customer enables this function in the user mode.
Mode 1: No fusing idling, transfer roller voltage is increased
Mode 2: Fusing unit rotates for 30 seconds before a job, transfer roller voltage is
increased.
Mode 3: Fusing unit rotates for 60 seconds before a job, transfer roller voltage is
increased.
CÓPIA NÃO CONTROLADA