Technical information

Ricoh Embedded Software Architecture (ESA) Device Client v1.4 Installation and Integration Guide
Appendix B: Configuring with AccuRoute Server v4.0
© 2013 by Omtool, Ltd. All rights reserved. Omtool, AccuRoute and the Company logo are trademarks of the Company. Trade names and trademarks of other companies appearing in this document are the property of their respective owners.
B-2
c Open the OmtoolXlet.dalp file using Notepad and make the following changes:
Service Path - Change the service path section to point to the proper directory and DLL.
Change to:
<argument>-servicepath:/WebAPI/scripts/omisapiu.dll</argument>
Display Mode - Change the display mode to whatever display mode is supported by the
device. For example:
<display-mode size="WVGA" />
Group Name - A group name in Ricoh ESA v1.4 is referred to as a SourceName. In the
following, Ricoh is the group name created in Admin:
<argument>-sourcename:Ricoh</argument>
d Save the OmtoolXlet.dalp file once the changes are made.
e Add the OmtoolXlet.dalp file back to the 33960192.zip file.
7 Install Ricoh 1.4 to the device using the Embedded Web Server of the Device or using an SD card
(refer to the Ricoh documentation for details).
8 Once the application is installed on the device start the application in the Extended Features Settings
of the device.