User's Manual

4-40
16
Press the key and perform air purge.
Start pushing ink out. (The screen to wait for air purge completion
is displayed.)
(1) Ink pushed out flows to the jig.
(2) Flow ink for about 30 sec. after ink started to flow.
(3) After flowing ink for about 30 sec., close the port.
(4) Change the jig to another port, flow ink for about 30 sec. in the
same way.
(5) After flowing ink for about 30 sec., close the port.
17
Press the key.
Pushing out ink stops.
18
Close the right maintenance cover.
19
Press the key.
The carriage moves to the cap position.
When the carriage moving has been completed, the air purge start
screen is displayed.
20
Press the key.
The screen to check air purge valve CLOSE is displayed.
21
Open the right maintenance cover.
22
Close the air purge valve.
Using a flat-blade screwdriver, rotate the air purge valve so that the slot of it may be vertical.
23
Close the right maintenance cover.
24
Press the key.
Cleaning is performed.
When cleaning has been completed, the screen returns to [FILL
UP INK] of the maintenance menu.
25
Press the key several times to end the setting.
When removing the jig, ink may leak. Put a paper towel etc. around the port.
AIR PG
COMP LETED [ ENT ]
Ink
Reference value :
About 10cm
CAPP I NG POS I T I ON
MOVE START [ ENT ]
PLEASE WA I T
AIR PG
END< >START
AIR PG VALVE CLOSE
COMP LETED [ ENT ]
** CLEANING **