Setting nozzle face cleaning time
When the set time has passed, nozzle face of the head is cleaned automatically to remove ink droplets on the
nozzle face.
In case that deflection, nozzle missing, or symptom which ink droplets fall down occurred, increase the level for
each type. If you increase the level, the intervals become shorter.
1
Press the key in LOCAL.
2
Press the key.
3
Press to select [INTERVAL WIPING].
4
Press the key.
5
Press to select types.
Set Value : TYPE1, TYPE2
TYPE1 is simple wiping performed for a short period.
TYPE2 is normal wiping performed for a long period.
6
Press the key.
7
Press to set levels, and press the
key.
Set Value : Lv1 to Lv6, MANUAL
When Lv1 to Lv6, the operation interval is changed automatically depending on the device temperature.
The cleaning interval is the longest when Lv1 is selected, and becomes shorter as you select higher
levels.
When [MANUAL] is set, set the intervals ins step8.
8
Press to set intervals, and press the
key.
Set Value :TYPE1: 90 to 600 sec
TYPE2: 10 to 90min
Example of behavior: When it is set to 90Sec, wiping is performed one head by one per 45Sec.
9
Press the key several times to end the setting.