Service manual

ADF Disassemble Procedure
SM 4-47 M085/M086
Replacement
and
Adjustment
5. Release the Hook [A] to remove the ADF sensor PCB ASSY [B] from the Lower document
chute ASSY [C].
6. Disconnect the Connector [D] from the ADF sensor PCB ASSY [B].