Service manual
Maintenance Mode
M085/M086 5-2 SM
5.1.2 HOW TO ENTER THE END USER-ACCESSIBLE
MAINTENANCE MODE
The maintenance-mode functions listed on the next section should be accessed by service
personnel only. However, you can allow end users to access some of these under the guidance
of service personnel by phone.
The end user-accessible functions are shaded in the table given on the next section. (codes 06,
09, 10, 11, 12, 25, 43, 53, 54, 80, 82, 87 and 91)
Function code 10 accesses the worker switches, each of which has eight selectors. You should
not allow end users to access all of those selectors, but you can allow them to access
user-accessible selectors which are shaded in the worker switch tables in p.5-50 "Worker
Switch Settings (WSW)".
The service personnel should instruct the end users to follow the procedure given below.
1. Press in the following order the Menu, Start, Menu, and
button. The "MAINTENANCE
06" appears on the LCD.
2. To access any other function code, call up the desired code using the
and buttons or
numerical buttons. Then press the OK button.
To switch the machine back to the standby state, press the Stop/Exit button. When each of the
user-accessible functions is completed, the machine automatically returns to the standby state.
5.1.3 LIST OF MAINTENANCE-MODE FUNCTIONS
Function Code Function Reference Page
01 EEPROM Parameter Initialization p.5-4
05 Printout of Scanning Compensation Data p.5-5
06
Placement of CIS Unit Position for
Transportation
p.5-7
08 ADF Performance Test p.5-8
09 Test Pattern p.5-9
10 Worker Switch (WSW) Setting p.5-10
11 Printout of Worker Switch Data p.5-15
12 Operational Check of LCD p.5-16