data.
Selector 2: Use of non-standard commands
If this selector is set to "0," the machine can use non-standard commands (the machine's
native-mode commands, e.g., NSF, NSC, and NSS) for communications. If it is set to "1,"
the machine will use standard commands only.
Selectors 3 and 4: No. of retries
These selectors set the number of retries in each specified modem transmission speed.
Selector 5: T5 timer
This selector sets the time length for the T5 timer.
Selector 6: T1 timer
This selector sets the time length for the T1 timer.
Selectors 7 and 8: Timeout for response from the called station in automatic sending
mode
If the machine (calling station) receives no response (no G3 command) from the called
terminal in automatic sending mode for the period specified by these selectors, it