Service manual
Worker Switch Settings (WSW)
M085/M086 5-86 SM
5.3.25 WSW24
Selector No. Function Setting and Specifications
1
2
Maximum OGM recording time
No. 1 2
0 0 : 15 sec.
0 1 : 20 sec.
1 0 : 30 sec.
1 1 : 50 sec.
3
4
Time length from CML ON to start of
pseudo ring backtone transmission
No. 3 4
0 0 : 4 sec.
0 1 : 3 sec.
1 0 : 2 sec.
1 1 : 1 sec.
5 to 8 Not used.
Selectors 1 and 2: Maximum OGM recording time
These selectors set the allowable maximum recording time for an OGM.
Selectors 3 and 4: Time length from CML ON to start of pseudo ring backtone
transmission
These selectors set the length of time from CML-ON up to the start of pseudo ring backtone
transmission.
In models with OGM facilities, the settings made by these selectors also apply to the length
of time from CML-ON up to the start of OGM transmission.