Service manual
Worker Switch Settings (WSW)
M085/M086 5-98 SM
5.3.39 WSW38
Selector No. Function Setting and Specifications
1
2
Setting of the equalizer
No. 1 2
0 0 : Automatic
0 1 : Automatic
1 0 : Fixed to 4 points
1 1 : Fixed to 16 points
3 Sending level of guard tone at phase 2 0: Normal - 7 db 1: Normal
4
Stepping down the transmission speed
at fallback each
0: 2,400 bps 1: 4,800 bps
5
6
Automatic control of modem's EQM
gain for proper transmission speed
choice
No. 5 6
0 0 : For higher transmission
speed than the current setting
0 1 : No change from the current
setting
1 0 : For lower transmission
speed than the current setting
1 1 : For further lower
transmission than the setting
made by 1, 0
7
Redialing when a communications
error occurs
0: ON 1: OFF
8 Detection of CED for stopping CNG 0: ON 1: OFF
WSW38 takes effect only when the V.34 mode is permitted (WSW19, selector 7) in
models supporting V.34 mode.
Selectors 1 and 2: Setting of the equalizer
These selectors set the equalizer's training level to be applied if the machine fails to send
training due to weak line connection. If these selectors are set to "0, X," the modem will
automatically set the appropriate training level.