Service manual
Worker Switch Settings (WSW)
SM 5-109 M085/M086
Service
Maintenance
5.3.60 WSW59
Selector No. Function Setting and Specifications
1
USB serial number (SN) transmission
enabled/disabled
0: USB serial number
transmitted/ USB serial number
not transmitted
1: Frame length selection
2
Extension of waiting time between the
ANSam-DIS
0: Valid 1: Invalid
3 to 8 Not used.
Selector 1: Frame length selection
This is intended to prevent the problem of a continued increase in USB ports when serial
numbers are transmitted from the MFC to a Windows Vista-based PC.
It is intended only to prevent a problem specific to Windows Vista; its default setting is "0:
USB SN enabled."
Selector 2: Extension of waiting time between the ANSam-DIS
When send from the G3 to the FAX machine of the G4, extend the waiting time between the
ANSam-DIS from 75ms to 450ms in expectation of the switching time of the echo canceller
of sending side. its default setting is "0: Valid"
5.3.61 WSW60
Not used.
5.3.62 WSW61
Not used.
5.3.63 WSW62
Not used.
5.3.64 WSW63
Not used.