Service manual
Others Problems
M085/M086 6-86 SM
6.11 OTHERS PROBLEMS
6.11.1 THE MACHINE IS NOT TURNED ON, OR THE LCD
INDICATION DOES NOT APPEAR.
Possible cause and Remedy
1. Harness connection failure of panel PCB
Is the harness of the panel PCB ASSY connected correctly?
No: Reconnect the panel PCB ASSY harness.
2. Panel PCB failure
Is the problem solved after replacing the panel PCB ASSY?
Yes: Replace the panel PCB ASSY.
3. LCD failure
Is the problem solved after replacing the LCD?
Yes: Replace the LCD.
4. LVPS PCB failure
Is the problem solved after replacing the LVPS PCB unit?
Yes: Replace the LVPS PCB unit.
5. Main PCB failure
Is the problem solved after replacing the main PCB ASSY?
Yes: Replace the main PCB ASSY.
6.11.2 THE FAN DOES NOT WORK.
Possible cause and Remedy
1. Harness connection failure of the fan motor 60 ASSY.
Is the harness of the fan motor 60 ASSY connected correctly?
No: Reconnect the harness of the fan motor 60 ASSY correctly.
2. Toner LED PCB ASSY failure
Is the problem solved after replacing the toner LED PCB ASSY?
Yes: Replace the toner LED PCB ASSY.
3. Main PCB failure
Is the problem solved after replacing the main PCB ASSY?
Yes: Replace the main PCB ASSY.