Service manual
Firmware Update
SM 5-1 M145/M146/M147/M148/M149/M150/M151
System
Maintenance
Reference
5. SYSTEM MAINTENANCE REFERENCE
5.1 FIRMWARE UPDATE
The machine firmware can be updated with packages downloaded from a Web site. The firmware
update procedure is described in the Operating Instructions and can be performed by the
operator.
5.1.1 BEFORE UPDATING THE FIRMWARE
Before you update the firmware:
Print a Configuration Page before and after updating the firmware.
Make sure that the machine is on and connected to the PC by its USB cable.
Never disconnect the USB cable while the firmware is being updated.
Make sure that the PC is set so it does not enter standby mode or sleep mode automatically
during the firmware update. The firmware update may take a while to complete, so you may
need to switch off the standby or sleep mode settings in the PC operating system.
An Engine firmware update failure may trigger SC670, which can only be cleared by
replacing the main board.
Because of this, make sure to do the following:
Always update the firmware in READY mode.
M135, M141, M143, M167, M149, M168, M150, M151, and M169 only: Unplug the fax
cable before starting the update.
Do not cut the power, unplug the USB cable, or do any other operation during the update.
5.1.2 FIRMWARE UPDATE PROCEDURE
1. Start Smart Organizing Monitor.
2. Open the List/Test drop-down list, select Configuration Page, and then click [Print].