Service manual
Basic Procedures
SM 4-5 M145/M146/M147/M148/M149/M150/M151
Replacement
and Adjustments
An AIO can be refilled up to three times (this is the approximate service life of the
drum).
Front Cover
1. Pull the paper feed tray out of the machine.
2. Press in and release either peg on the front cover [A].