Service manual

Bit Switches
M381 92 SM
G3 Switch 0A [SP No. 1-105-011]
No FUNCTION COMMENTS
0-1
Maximum allowable carrier
drop during image data
reception
Bit 1: 0, Bit 0: 0 = 200 (ms)
Bit 1: 0, Bit 0: 1 = 400 (ms)
Bit 1: 1, Bit 0: 0 = 800 (ms)
Bit 1: 1, Bit 0: 1 = Not used
These bits set the acceptable modem carrier
drop time at the non ECM mode.
Try using a longer setting if error code 0-22 is
frequent.
2
Select cancellation of
high-speed RX if carrier signal
lost while receiving
0: Off
1: On
This switch setting determines if high-speed
receiving ends if the carrier signal is lost when
receiving during non-ECM mode
3
Not used
Do not change the settings
4
Maximum allowable frame
interval during image data
reception.
0: 5 s 1: 13 s
This bit set the maximum interval between EOL
(end-of-line) signals and the maximum interval
between ECM frames from the other end.
Try using a longer setting if error code 0-21 is
frequent.
5
Not used
Do not change the settings.
6
Reconstruction time for the first
line in receive mode
0: 6 s 1: 12 s
When the sending terminal is controlled by a
computer, there may be a delay in receiving
page data after the local machine accepts
set-up data and sends CFR. This is outside the
T.30 recommendation. But, if this delay occurs,
set this bit to 1 to give the sending machine
more time to send data.
Refer to error code 0-20.
ITU-T T.30 recommendation: The first line
should come within 6 s of CFR.
7
Not used
Do not change the settings.